Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP19-0117
Parcel: 12701008A

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP19-0117
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2019 SBEASLE1 START PLANS SUBMITTED Completed
08/21/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office FROM: David Rivera, PDSD Zoning Review Section
PROJECT: At Home - Retail Use Group / General Merchandise Sales
Development Package (1st Review) - 5255 E. Broadway Boulevard
DP19-0117 - C-1 Zoning (Revision 1)
TRANSMITTAL DATE: August 21, 2019
DUE DATE: August 30, 2019
COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 7, 2020.
1. COMMENT: Zoning has reviewed the revisions listed in the revision letter and the proposed changes to the plans. Address the following comments and resubmit for review. (The zoning comments are minor and zoning is willing to do an over the counter digital review once the corrections have been made on the plans.)
2. COMMENT: 2-06.4.9.H.5.d and 2-06.4.9.R - Include a fully dimensioned detail drawing of the relocated bicycle parking location. The bicycle parking area must meet the minimum width and access requirements as well as provide a minimum width of four feet clear for pedestrian access.
Demonstrate that short term bicycle parking facilities are within 50 feet of the main public entrance.
3. COMMENT: The accessible parking sign must be revised to show a clear dimension from the top of pavement to the bottom of the lower sign (Van Accessible Sign) on the pole.
4. COMMENT: Draw and Label the Main public entrance.

If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected DP Plans
08/29/2019 LOREN MAKUS ENGINEERING REVIEW Approved
08/30/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change NOTE: We will be closed Monday, Sept. 2, for Labor Day.

REVISION PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: DP19-0117
Description: SITE - At Home, new truck well, relocate accessible parking spaces.
The fee balance is $0 (zero). Thank you for your payment.
To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically throughout the day.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter
2) Plan Set (or sheets)
3) Any other items requested by review staff
After the corrections are made, please name your Revision #1, 2nd submittal documents accordingly, for example: REV-1_2_Plan_Set.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2019 SBEASLE1 OUT TO CUSTOMER Completed