Permit Number: DP19-0112
Parcel: 14029008B

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0112
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2019 SBEASLE1 START PLANS SUBMITTED Completed
06/18/2019 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: McDonald's @ Valencia & Country Club - Drive-Thru Modification
Development Package (2nd Review)
DP19-0112

TRANSMITTAL DATE: June 18, 2019



COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.5 - Remove the Development Package PDSD Approval stamp from the plan and provide a three-inch by five-inch space in the lower right quadrant of each sheet, in the same location, for an electronic approval stamp.

CONTENT REQUIREMENTS

2. 2-06.4.3 - Provide the TSMR case number, DS19-06 , adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. 2-06.4.7.A.6.a - As a general note provide the TSMR case number, date of approval, what was modified and if applicable any conditions of approval.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.H.5.a - Clarify why there are two different vehicle parking calculations on the plan, one on sheet C1 and one on SP-1.

5. 2-06.4.9.R - Sheet S-1, ENLARGE DRIVE-THRU PLAN, there is a site plan note 9 that calls for "NEW CURB". The keynote does not appear to be pointing at a curb and the striped area just to the north is required to be physically separated from the vehicle parking space.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/18/2019 SSHIELD1 ZONING HC REVIEW Reqs Change See Zoning comments
06/19/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved
06/19/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
06/20/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
The fee balance is $0 (zero).
Activity Number: DP19-0112
Project Description: SITE/GRADING - McDonalds USA, LLC, commercial restaurant.
For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, please name your 3rd submittal documents accordingly, for example: 3_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (lists changes made to the Plan and which reviewer comments you are responding to)
2) Complete Plan Set (all pages, full set)
3) Any other items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle.
Thank you.
Sharon Beasley, Permit Technician

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
06/20/2019 SBEASLE1 OUT TO CUSTOMER Completed