Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP19-0107
Parcel: 141186070

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0107
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/13/2019 PAUL CAMARENA ZONING REVIEW Approved
10/07/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
10/21/2019 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change DATE: October 21, 2019

TO: John Beall FROM: Alexandra Hines, AICP
Entitlements Section Manager Lead Planner

SUBJECT: Rezoning for (C9-18-21) Surf Thru, Inc - Old Vail Road based on Development Package of (DP19-0107) Surf Thru Express Carwash


The above referenced development package has been conditionally-approved by the City Development Review Committee (CDRC) to prepare the rezoning ordinance for Mayor & Council adoption. Please submit five (5) weeks in advance to the next available Mayor & Council meeting, November 19, 2019.

Conditions of the rezoning per the decision of the Mayor & Council are hereby met.

No permits or development approvals [which includes excavation, grubbing, grading, paving] may be granted that are in furtherance of the rezoning request until the 30 days have lapsed and the conditions of rezoning have been met per UDC 3.5.3.J.6. As the applicant, please remind the contact below when the 30 days near. At that time, staff will review the ordinance adopted by Mayor & Council and the applicant will receive an approval notification to obtain the permit for the development package.

Should you have any questions, please contact Alexandra Hines, AICP at (520) 837-6975 or alexandra.hines@tucsonaz.gov.

Attachment: Development Package

xc: Project Record by Activity Number
10/21/2019 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change PLAN APPROVAL NOTICE / Request for documents
Please follow the steps below to finalize the approval process

DESCRIPTION: SITE/GRADING/SWPPP - Surf Thru Express Carwash, Houghton Town Center.

PERMIT: DP19-0107
For faster service, please include this number on all correspondence.

FEE BALANCE: $0 (zero)
YOUR NEXT STEPS - Reply to this email and attach the following documents.
1. City of Tucson Permit, checkmarked and signed (see attached). Before signing, double-check information (owner name, etc.) for accuracy.
2. Letter of Intent from the Contractor: Includes the project title, project address, Activity Number, ROC license number
3. Fugitive Dust Activity Permit: Contact Pima CountyDEQ at (520) 724-7400

AFTER REPLYING with the required documents, allow a few days for our staff to stamp the plans, upload them to PRO (www.tucsonaz.gov/pro), and send you a "Plan Issued" email notification. That email will include an online link to the approved stamped plans and a list of required inspections.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
10/21/2019 AHINES2 OUT TO CUSTOMER Completed