Permit Number: DP19-0107
Parcel: 141186070

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0107
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2019 SBEASLE1 START PLANS SUBMITTED Completed
07/16/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
07/18/2019 DAVID RIVERA ZONING HC REVIEW Approved
07/18/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Surf Thru Express - Commercial Use / Automotive Service Repair - Full Service Car Wash
Development Package (2nd Review) Ref. C9-18-21 - 10206 E. Vail Road
DP19-0107 - C-1/I1 to All I-1

TRANSMITTAL DATE: June 5, 2019
DUE DATE: June 5, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 30, 2020.


***Please address the Follow up Comments Only from this review.

1. Follow up To Previous Comment 3: List the Sequence Number 20131360085 as part of the brief legal description in the title block of all DP sheets.

2-06.4.2 - The title block shall include the following information and be provided on each sheet:
2-06.4.2.B - A brief legal description and a statement as to whether the project is a re-subdivision are to be provided. On re-subdivisions, provide the recording information of the existing subdivision plat;

Previous Comment 3: Include a brief legal description in the title block of each sheet.


2. Follow up to Previous Comment 7: List the applicable Use Specific Standard Section 4.9.13.Q.

2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

Previous Comment 7: Revise note 3 under the DP Notes as follows; "Existing use is vacant, proposed use is Commercial Use Group - Automotive Washing - Self Service" (unless this is a full service use).


3. Follow up to Previous Comment 8: In the previous review I requested that the AEZ note be added to the DP. I inadvertently listed Article 6 which is incorrect. Please revise the article number to 5in note 4 under the Overlay Zones text block.

Previous Comment 8: Under the Overlay Zones criteria text block on sheet 2, include a note that states that "This development is designed to comply with the Regulations of UDC Article 5, AEZ Section 5.6."


4. Follow up to Previous Comment 10: Provide the processed Pima County Tax Parcel Combo documents with the next submittal of the DP.

2-06.4.9.E - Proposed land splits or existing lot lines shall be drawn on the plan with dimensions and the identification number and approximate square footage of each lot. (Please be aware that, if land division occurs and the number of lots falls within the definition of subdivision, a subdivision plat is required.) Land splits require a separate permit and review.

Previous Comment 10: This project is proposed for development over 4 previously recorded lots. Prior to approval of the DP the lots must be combined by means of recording a metes and bounds survey which encompasses the development site area or by processing a Pima County Tax Parcel combination. Contact the Pima County Assessor's office for the latter option.



If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/23/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL
SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data

Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that all Zoning comments are addressed:

This project is proposed for development over 4 previously recorded lots. Prior to approval of the DP the lots must be combined by means of recording a metes and bounds survey which encompasses the development site area or by processing a Pima County Tax Parcel combination. Contact the Pima County Assessor's office for the latter option.
07/24/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved
07/25/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.

Permit/Activity Number: DP19-0107
Description: SITE/GRADING/SWPPP - Surf Thru Express Carwash, Houghton Town Center.
Project Manager: Mark.Castro@TucsonAz.gov, (520) 837-4979
The fee balance is $0 (zero).
Review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Name your 3rd submittal documents accordingly, for example: 3_Plan_Set.
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other items requested by review staff
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2019 SBEASLE1 OUT TO CUSTOMER Completed