Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP19-0090
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 07/02/2019 | MASHFOR1 | COT NON-DSD | FIRE | Approved | |
| 07/22/2019 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: College Town - New Security Fence and Gates Development Package (1st Review) DP19-0090 TRANSMITTAL DATE: July 22, 2019 DUE DATE: July 30, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 27, 2020. CONTENT REQUIREMENTS 1. 2-06.4.3 - Provide the development package case number, DP19-090, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. 2-06.4.7.A.2 - Revise Zoning and Land Use Note 4 to include the square footage. 3. 2-06.4.7.A.6.a - As this site boarders on two streets listed on the MS&R map provide a general note on the cover sheet stating "THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)." 2-06.4.7.A.8 - For development package documents provide: 4. 2-06.4.7.A.8.b - Remove the lot coverage calculation from the plan as it is not correct and is not applicable. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 5. 2-06.4.9.H.5.a - Based on the provided vehicle parking space calculation this site does not meet code for the required number of vehicle parking spaces and you are proposing to remove vehicle parking spaces from the site. A Board of Adjustment for Variance will need to be applied for and approved prior to approval of this DP. Based on the information provide the required number of vehicle parking spaces is 310, provided is 236. 6. 2-06.4.9.H.5.a - The required number of handicap accessible spaces is not correct. Per 2018 IBC Table 1106.1, 151 to 200 requires 6 spaces. 7. 2-06.4.9.H.5.a - Demonstrate that the requirements of UDC Article 7.4.6.D.2.b are met at all proposed gate locations. 8. 2-06.4.9.H.5.d - Remove the short & long term bicycle parking calculation from the plan as it is not applicable. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 07/22/2019 | SSHIELD1 | ZONING HC | REVIEW | Passed | |
| 07/29/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 07/29/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Reqs Change | July 29, 2019 ACTIVITY NUMBER: DP19-0090 PROJECT NAME: College Town PROJECT ADDRESS: 1300 E Ft Lowell PROJECT REVIEWER: Zelin Canchola TDOT Resubmittal Required: The following items must be revised and added to the Development plan. 1. Eastern Driveway proposed gate location is not acceptable. A turnaround area shall be located within the development boundary outside of the arterial (Ft Lowell) right of way. 2. Provide ADA pedestrian connection within the right of way to new Pedestrian gate. If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov |
| 08/01/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 08/02/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - The reviews have been completed - A resubmittal is required Permit/Activity Number: DP19-0090 Description: SITE - College Town, modification of existing parking lot to add vehicular gates. The fee balance is $0 (zero). Thank you for the payment. To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set. Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (listing your response to reviewer's comments) 2) Plan Set (all pages, full set) 3) Any other items requested by review staff Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/02/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |