Permit Number: DP19-0069
Parcel: 10509546B

Address:
78 W RIVER RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0069
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2019 SBEASLE1 START PLANS SUBMITTED Completed
04/24/2019 SBEASLE1 ENGINEERING REVIEW Passed
04/26/2019 MASHFOR1 COT NON-DSD FIRE Approved
05/08/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/16/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
05/21/2019 DAVID RIVERA ZONING HC REVIEW Approved
05/21/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: DP19-0069
Project Description: SITE - Earth's Healing Dispensary, north facade improvement, exterior canopy addition.
To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, please name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, include the Activity Number.
1) Comment Response Letter (lists changes made to the Plan and which reviewer comments you are responding to)
2) Corrected Plan Set (all pages, full set)
3) Any other items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero).
Thank you.
Sharon Beasley

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
05/21/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Earth's Healing's MM Dispensary - Building Expansion and Outdoor Fenced Area
Development Package (2nd Review) 78 W. River Road
DP19-0069 - C-2 Zoning / Related to T19CM02955 / SCZ Overlay Applicable

TRANSMITTAL DATE: May 21, 2019
DUE DATE: May 22, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 25, 2020.


2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

1. COMMENT: The owner's information was not fully listed. Include the name and, phone number and email address.


2-06.4.2 - The title block shall include the following information and be provided on each sheet:
2-06.4.2.B - A brief legal description and a statement as to whether the project is a re-subdivision are to be provided. On re-subdivisions, provide the recording information of the existing subdivision plat;

2. COMMENT: Include the following in the legal description; "NORTHMALL CENTRE PTN OF E161.05' W378.74', LOT 1"


2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan.

3. COMMENT: Include a general note that states that the development has been designed to comply with the Scenic Corridor UDC Section 5.3.


4. COMMENT: After discussing the resubmittal with Gwen Stanley on May 21, it is clear that there is not additional use area expansion. The existing canopy area is an existing enclosed area and is to be modified only. The proposed canopy is an open roofed structure only not a use area. The fenced area along the Stone Loop frontage is an employee break area and not a Dispensary use area.

The remaining comments are minor and can be reviewed under a Digital over the counter zoning review on the next submittal.


If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

Final Status

Task End Date Reviewer's Name Type of Review Description
05/21/2019 SBEASLE1 OUT TO CUSTOMER Completed