Permit Number: DP19-0064
Parcel: 30503004B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0064
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2019 SBEASLE1 START PLANS SUBMITTED Completed
03/21/2019 MASHFOR1 COT NON-DSD FIRE Approved
03/22/2019 AHINES2 ZONING HC REVIEW Approved
03/22/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change 7.7. NATIVE PLANT PRESERVATION
7.7.3. APPLICABILITY

The provisions of this section apply to all development as listed below.

A. New Development

All new development proposed in the City of Tucson shall comply with the standards of this section.

Exceptions
Projects on a site or parcel that contains Protected Native Plants that will not be substantially impacted by development on the site as demonstrated by the applicant per this section and subject to approval through procedures established at the PDSD, provided that construction occurs per the approved plan.
It appears that more than a few Protected Native Plants are impacted by development. The NPPO Application for Exception does not apply.
Submit the following for review:
7.7.4. GENERAL PROVISIONS AND STANDARDS

Submittal Requirements

A Native Plant Preservation Plan in accordance with Section 2-12.0.0 of the Administrative Manual is required for all projects under the applicability of this section according to the methodology selected by the applicant as outlined in Section 7.7.5, Plant Preservation Standards

Additional comments may apply.
03/22/2019 ALEXANDRA HINES ZONING REVIEW Approved
04/11/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: DP19-0064
Project Description: SITE - COT Regional Public Safety Training, 8 solar canopies, 643.8 KW-DC, 486 KW-AC photovoltaic project.
To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, enter the Activity Number.
1) Comment Response Letter (lists changes to the Plan and which reviewer comments are being addressed)
2) Corrected Plan Set (all pages, full set)
3) Items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero).
Thank you.
Sharon Beasley

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
04/11/2019 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Reqs Change April 11, 2019
Sharon Beasley,Permit Technician
City of Tucson
Public Works Buildings - 201 North Stone Avenue
Tucson, AZ. 85701
RE: DP19-0064 City of Tucson Regional Public Safety, 1st Submittal, Received March 20, 2019
Dear Ms. Beasley,
Thank you for the opportunity to comment on DP19-0064, City of Tucson Regional Public Safety, 1st Submittal, a development package application for an approximately 1 acre site, located southeast of the intersection of East Old Vail Road and South Wilmot Road. The property is zoned Rural Homestead (RH), with the proposed development being photo voltaic (solar panel) shade canopies.
This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.
The Tucson Airport Authority conditionally approves the subject request contingent upon the following condition of approval, as noted below. This condition shall be identified in the general notes of the revised development plan.
Condition of approval:
1. "According to the FAA Notice Criteria Tool, 1) this project is located in proximity to a navigation facility and could impact navigation signal reception and 2) this project exceeds an instrument approach area by 123 feet and an aeronautical study is needed to determine if it will exceed subpart C of 14CFR Part 77. The applicant shall file Form 7460 with the FAA at least 45 days before construction activities begin for the project. It is highly recommended that the applicant file earlier than 45 days to provide the applicant with sufficient time to respond to any concerns which are identified by the FAA. Any cranes used which are used must also be identified with Form 7460. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp"

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.
Respectfully,
Scott Robidoux, Senior Airport Planner
Tucson Airport Authority

Final Status

Task End Date Reviewer's Name Type of Review Description
04/11/2019 SBEASLE1 OUT TO CUSTOMER Completed