Review Date Reviewer's Name Type of Review Description Status Comments
03/12/2019 SBEASLE1 START PLANS SUBMITTED Completed
03/12/2019 SBEASLE1 UTILITIES SOUTHWEST GAS Passed This agency was notified for their information only. A review is not required.
03/12/2019 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed This agency was notified for their information only. A review is not required.
03/12/2019 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed This agency was notified for their information only. A review is not required.
03/13/2019 MASHFOR1 COT NON-DSD FIRE Approved Please provide the deferred submittal to TFD for any modifications or expansion of the fire sprinkler system
04/01/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved ***Attachment can be viewed under documents table on PRO (SIRE).***

WR#6267013 March 28, 2019

City of Tucson
Attn: Sharon Beasley
Planning and Development Services
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Dear Ms. Beasley:

SUBJECT: Jim Click Chrysler
DP19-0057

Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted March 12,
2019. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed
development.

The provided plans show our existing facilities correctly, for the existing 3Ø transformer primary cable, and 3Ø
service run. The service shows it is in the new area of the addition. It doesn't show where the new service will
be located once the new structure is in place.

A possible service relocation may be required. All 3Ø UG service conductors are furnished by the customer (no
larger than 500kcmil is acceptable). We will need to calculate the new load to see if upgrading the existing pad
mount 3Ø transformer will need to be upsized.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any
relocation costs will be billable to the customer.

When the approved plans have been received, and the customer has a permit, please call the New Construction
Department at (520) 918-8300 to complete an application for electric service. TEP will require a full set of
approved plans, including site, electrical load, and the electrical one-line diagram.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please contact the area Designer, Susie Petty, at (520) 917-8741.

Sincerely,
Linda Metzer
Linda Metzer
Office Support Assistant
Design/Build
lm
Enc.
cc: CDRC@tucsonaz.gov, City of Tucson (email)
S. Petty, Tucson Electric Power
04/04/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change April 4, 2019
ACTIVITY NUMBER: DP19-0057
PROJECT NAME: Jim Click remodel
PROJECT ADDRESS: 701 W Aouto mall Dr
PROJECT REVIEWER: Zelin Canchola TDOT

Resubmittal Required: The proposed work in the right of way is acceptable, However the standard details will need to reference PAG standard details.

If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
04/05/2019 ALEXANDRA HINES COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.
Howard B. Dutt, RLA
Landscape ArchitectTucson Parks & Recreation(520) 837-8040
Howard.Dutt@tucsonaz.gov
04/08/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL
SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
The landscape plan will contain the following identification in the lower right corner of each sheet:
Any relevant case numbers for reviews or modifications that affect the site.
Indicate graphically compliance with conditions of Annexation Agreement.

ARTICLE 7: DEVELOPMENT STANDARDS

7.6. LANDSCAPING AND SCREENING

7.6.2. APPLICABILITY

The provisions of this section apply to the following:
A. All new development; and,
B. Expansion of existing development, as provided below:
1. Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:
a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.

If necessary show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.

Ensure that all Zoning and Engineering comments and concerns are addressed.

Additional comments may apply
04/08/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
04/10/2019 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved
04/15/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0057

1) Where pedestrian circulation path connects to diamond shaped brick area with flagpole. Provide dimensions around flagpole showing that a minimum 4' path is provide. Also add keynotes indicating that the maximum accessible cross slope and running slope needs to be maintained
2) Since the new proposed pedestrian pathway connecting the buildings to Auto Mall Drive needs meet ADA requirements, show the existing cross slopes and running slopes for the paved area
3) Sheet C4. There appear to be a couple random plants in the parking area along the pedestrian path. Remove as needed
4) For customer parking/accessible parking area show on plans the require wheel stops. Show that with a 2.5' vehicle overhang the sidewalk in front of the parking area is a minimum 4' wide
5) Provide dimensions for site visibility triangles. Provide site visibility triangles at all driveway connections to W Auto Mall Dr. Site Visibility Triangles adhere to City of Tucson (COT) Technical Standards Manual (TSM) Section 10-01.5.0
6) Provide a fully dimensions Vehicle Use Area. Show widths for all drives and access lanes. It looks like the new proposed building reduces the drive/pall width on the western side
7) Sheet 6. Keynote 4 does not point to the existing trash enclosure
8) Sheet C2, Keynote 7, should reference Detail 6 C4 not detail 5 C4. Correct as needed
9) Show on plans the service vehicle maneuvering areas according to COT Technical Standards Manual section 8. It does not look like the current/proposed position of the trash enclosure will accommodate the service vehicle turning radius

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
04/17/2019 DAVID RIVERA ZONING HC REVIEW Reqs Change See zoning comments.
04/17/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Jim Click Chrysler - Retail - Auto Sales Use
Development Package (1st Review)
DP19-0057 - C-3 Zoning - 701 W. Auto Mall Drive

TRANSMITTAL DATE: April 17, 2019
DUE DATE: April 10, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 7, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section


2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

1. COMMENT: List the Owner / Developer Contact and email address information on sheet one.


2-06.4.2.B - A brief legal description and a statement as to whether the project is a re-subdivision are to be provided. On re-subdivisions, provide the recording information of the existing subdivision plat;

2. COMMENT: The legal description listed on the DP does not match what is listed under the Pima County Assessor's legal description. Per the Pima County Revised Map and Plat and legal description, the subject parcel is made up of a portion of lot 15 and portion of lot 16. Correct the legal description accordingly in the title block of all plans sheets and under the Legal Description heading on the cover sheet.


2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

3. COMMENT: Provide the development package case number, DP19-0057, adjacent to the title block on each sheet.

List the administrative street address next to the title of all plan sheets.


2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

4. COMMENT: Correct the use specific standard listed to the correct standard 4.9.9.G.1 & .2


2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan.

5. COMMENT: List as reference the Annexation case number C9-85-44 next to the title block of all plans sheets.


2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

6. COMMENT: Draw in the existing conditions within 50 feet for the west, east and south sides of the subject property including 50 feet across Auto Mall Drive as noted by the standard above.


2-06.4.8.B - All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided.

7. COMMENT: Clarify what is meant by "Per (R2) SCH. B ITEM No. 6" listed on the 9.5' and 10'x10' easements?

Label the 9.5' easement on sheet 2.


2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

8. COMMENT: Draw and label all the street information as noted by the standard above.


2-06.4.9.H.4 - Indicate if existing streets are public or private; provide street names, widths, curbs, sidewalks, and utility locations, all fully dimensioned.

9. COMMENT: Label the Auto Mall Drive and Auto Sprint Road as Public.


2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

10. COMMENT: Clearly define the vehicle display spaces and the required parking spaces. Dimension the PAALs adjacent to the required parking spaces. Vehicle display spaces do not count towards the number of required parking spaces for the use.


2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

11. COMMENT: The number of required parking spaces will be reevaluated on the next submittal once comment 10 is addressed. Additional comments may be forth coming on this requirement.

Include dimensioned detail drawings for the standard parking spaces and accessible spaces with access aisles which include a van accessible space(s).


2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided.

12. COMMENT: Vehicle Rental and Sales Use has a specific number of short and long term bicycle parking requirements. Two short term facilities are required and five long term facilities must be provided. Revise the bicycle parking calculation to correctly list the long term bicycle parking spaces required and provided.

Also, revise the uses listed under the bicycle parking to "Vehicle Rental and Sales Use".

Include the (short and long term facilities) fully dimensioned details drawings as noted in the standard above.


2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

13. COMMENT: List the square footage and building heights within the building footprints of the existing and new buildings.


2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

14. COMMENT: Demonstrate required sidewalk system from the new buildings to the existing pedestrian circulation system. A minimum four foot wide sidewalk is required when adjacent to a building and PAAL or drive lane. The pedestrian sidewalk system must be provided out to the Pedestrian sidewalk in the access easement along the street frontage. Assure that the cross and longitudinal slopes that comply with ADA standards are labeled.

Label the Pedestrian walkway system, dimension the sidewalks and label the cross and longitudinal slopes.

2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required.

15. COMMENT: Indicate on the site plan sheet the location of existing or proposed free standing monument signage.



If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/18/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: DP19-0057
Project Description: SITE/GRADING - Jim Click Chrysler Jeep - expansion, remodel, and exterior image improvements.
To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, include the Activity Number.
1) Comment Response Letter (lists changes made to the Plan and to which reviewer comments you are responding)
2) Corrected Plan Set (all pages, full set)
3) Items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero).
The Project Manager can be reached via email or phone: Nicholas.Ross@TucsonAz.gov, (520) 837-4029.
Thank you.
Sharon Beasley

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
04/18/2019 SBEASLE1 OUT TO CUSTOMER Completed