Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0056
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/11/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/07/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Ensure that IID Design Professional, Zoning and Engineering comments are addressed prior to landscape approval. Once all the comments are addressed an over the counter review can be performed upon resubmittal. |
| 10/08/2019 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: Elisa Hamblin, AICP; Principal Planner Zoning Review Section PROJECT: The Hub IV, 902 E Speedway Bl Development Package (3rd Review) DP19-0056 TRANSMITTAL DATE: October 8, 2019 DUE DATE: October 9, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 22, 2020. 1. Delete permitting note 3. It is incorrect and duplicative of permitting note 2. 2. Per previous comments, provide case number MGD-19-02 (T19SA00139) adjacent on the title block on all sheets. Sheets 17-21 are missing case numbers. 3. Per previous comments, correct Vehicular Parking Calculations on sheet 1. A Retail use requires the greater of 2 spaces or 1:2,000 sq. ft. per Main Gate Overlay C-5.a.1.ii. "Retail: Minimum of the greater of (a) 2 spaces or (b) 1 space per 2,000 square feet of GFA." Required parking should total 85 (76+2+7). Provided parking should total 85 (76+2+7). 4. Per previous comments, correct Bicycle Parking data. The calculations on sheet 1 are correct. The actual spaces on the plan on sheet 7 (C3.2) are correct. However, the notes on sheet 7 are incorrect. Street level (short-term) bike parking should list 7 non-residential and 46 residential spaces. Lower level (long-term) bike parking should list 2 non-residential and 28 residential spaces. 5. Per previous comments, revise sidewalk area on Park Av. A minimum of 4' from the back of the curb to the sidewalk and an 8' sidewalk clear area is required. A total of 12' must be shown from back of curb to either a building or planter. Proposed layout does not meet this standard. It is acknowledged the 8' clear area is met. However, the 4' area has not been provided. 6. Per previous comments, additional information is needed on required open space. The Open Space Calculations on sheet 1 are correct. The illustrated ground level space on sheet 6 (C3.1) appear correct. However, verification of proposed rooftop open spaces is required. Provide roof plan illustrating open space (with dimensions and/or square footage) to verify total amount provided. Alternately, update sheet 6 with outline of rooftop open space and dimensions/area shown along with the other illustrated open space. As the changes required on this development package are minimal, an over-the-counter review can be scheduled upon resubmittal. Please contact me directly to schedule or if you have questions about this transmittal at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/10/2019 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | Pima County Addressing approves DP19-0056 / Hub 4 on Campus / 3rd subm. for review. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV, Tucson, AZ 85701, (520) 724-9623 |
| 10/11/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 10/15/2019 | NROSS1 | DESIGN PROFESSIONAL | REVIEW | Approved | Date: October 12, 2019 From: Rick Gonzalez, Architect, City of Tucson On-Call Design Professional To: Sharon Beasley, Planning and Development Services Department (PDSD) Re: Design Professional review comments for the DP19-0056, Hub 4. After review, based upon Main Gate District (MGD) Document and Ordinance 11394, Section C-19, of the required plans and documents submitted to PDSD, I recommend approval of this project. The Hub IV Development Package Submittal makes reference to the Design Review Committee's reviews and conditions on the Development Site Plan Sheet C3.0. The Development Package presents attached building elevation images that verify compliance with the Design Package. Therefore, it is recommended to the Director that the Development Plan as resubmitted provides verification of compliance with the Design Package. With Regards, Rick Gonzalez COT DP |
| 10/15/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: DP19-0056 Project Description: SITE/GRADING/MGD - Hub 4 On Campus, Park Avenue, group dwelling, food service, and retail. Project Manager: Elisa.Hamblin@TucsonAz.gov, (520) 837-4966 The fee balance is $0 (zero). Thank you for your payment. To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number. (If information isn't shown yet, check back later as data uploads to PRO periodically.) Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (your response to the reviewer's “Requires changes” comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 4th submittal documents accordingly, for example: 4_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/15/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |