Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP19-0049
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/04/2019 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 04/01/2019 | NICHOLAS ROSS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Nick Ross Lead Planner PROJECT: Development Package (1st Review) DP19-0049 TRANSMITTAL DATE: April 1, 2019 DUE DATE: April 1, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 1, 2019. 1. "DP19-0049" must be on both sheets of the plan. 2. Proposed structure does not meet required setbacks on the north and south sides of property. Since this is a corner lot, the setback requirement on the south is 10 feet. The required setback on the north side of the property is 2/3 the height of the proposed structure which would equal 12 feet. The proposed setback on both the north and south side is 5'2". A DDO is required prior to zoning approval. A link to the application can be found here: https://www.tucsonaz.gov/files/pdsd/forms/2018_DDO_for_Setback_and_Height_UDC.pdf 3. Provide the depth of the motor vehicle parking spaces on the parking detail on Sheet 2. 4. Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. Once the DDO is obtained and the plans have been corrected with the changes outlined in the comments above, you can contact me directly for a counter review once your second submittal has been accepted online. If you have any questions about this transmittal, please contact me at Nicholas.Ross@tucsonaz.gov or (520) 837-4029. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/01/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 04/01/2019 | NROSS1 | ZONING HC | REVIEW | Passed | See zoning comments |
| 04/04/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. Provide dimensions for the existing sidewalk. If the existing sidewalk is less than 4 feet wide, it must be replaced with 5-foot sidewalk. 2. Check the keynotes. Some of the keynote descriptions don't seem to match the plan. 3. Revise references to the PC/COT standard details to the Appropriate PAG standard details. 4. Label the existing contours and list the contour interval near the north arrow and scale. 5. Provide representative proposed grades. 6. Show drainage patterns including roof drainage. |
| 04/08/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/09/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. Activity Number: DP19-0049 Project Description: SITE - Residential Care, Southern Heights, Lot 6, Block 6. To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.) After all corrections are made, name your documents accordingly – for example, a 2nd submittal document would be titled: 2_Plan_Set. Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, enter the Activity Number. 1) Comment Response Letter (lists changes to the Plan and which reviewer comments are being addressed) 2) Corrected Plan Set (all pages, full set) 3) Items requested by review staff After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero). Thank you. City of Tucson Planning and Development Services Attn: Sharon Beasley 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/09/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |