01/25/2019 SBEASLE1 START PLANS SUBMITTED Completed
01/30/2019 MASHFOR1 COT NON-DSD FIRE Approved
02/22/2019 ANDREW CONNOR NPPO REVIEW Approved
02/22/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
02/26/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: Solar Canopies over portion of existing parking spaces - Fort Lowell Park
Development Package (1st Review) - 2900 N. Craycroft Road
DP19-0019 - HRX-2 Zoning

TRANSMITTAL DATE: February 26, 2019
DUE DATE: February 25, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 24, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp.

1. COMMENT: Remove the Development Package PDSD approval stamp from all sheets. Reserve a three-inch by five-inch space in the lower right quadrant of each sheet for an approval stamp. The approval stamp will be applied electronically by PDSD staff.


2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

2. COMMENT: Provide the development package case number, DP19-0019, adjacent to the title block on each sheet.


2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan.

2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any.

3. COMMENT: The parcel is Zoned HRX-2. Prior to approval of the DP and building plans, a historic review and approval must be obtained through the HPZ review process. Contact Michael Taku at 520-837-4963 for information on the requirements and application for the HPZ review.

List as reference the case numbers associated with the HPZ review and approval next to the title block of all plan sheets.

List as a general note on the cover sheet: the overlay type (HPZ UDC Section 5.8), case number, date of approval, and any conditions of approval.

2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

4. COMMENT: Label the street names on sheet 2 with a legible font.


2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

5. COMMENT: Draw, dimension and label the parking space on the cross section drawing on sheet 4.

Label the 1 minimum setback of the roof overhang from the back of the PAAL / parking spaces.



If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

FROM: Andrew Connor
Planner

PROJECT:
DP19-0019
2900 N Craycroft Rd.
Solar Shade Structure.

TRANSMITTAL: February 28, 2019
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).


This site is located in the HRX-2 zone (UDC 4.7.7). A Public park is permitted in zone

The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A).

The applicant is proposing a 12' detached solar shade structure with a 455' setback to the West and a 399' setback to the East.
02/26/2019 DAVID RIVERA ZONING HC REVIEW Passed
03/04/2019 LOREN MAKUS ENGINEERING REVIEW Approved
03/05/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews are completed and a resubmittal is required.
Activity Number: DP19-0019
Project Description: SITE/SOLAR CANOPIES - Fort Lowell Park, City of Tucson
To see review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
Prepare a Comment Response Letter detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made, submit the following three items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
Enter the Activity Number in the Project Description field and name the file as directed, for example, second submittal: 2_Plan_Set.pdf. The plans will then re-enter a 20-working-day review cycle.
1) Comment Response Letter
2) Corrected plan set with all documents
3) Items requested by review staff
Please pay the assessed fees, or the Review fees at a minimum, at the permit counter or mail a check (payable to the City of Tucson, address is shown below) prior to the completion of the next review. Include the Activity Number on your check stub. The fee balance is $429.00.
Thank you.

Sharon Beasley
City of Tucson
Planning and Development Services
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
03/05/2019 SBEASLE1 OUT TO CUSTOMER Completed