Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP18-0314
Parcel: 10308001S

Review Status: Completed

Review Details: GRADING

Permit Number - DP18-0314
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2019 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: DP18-0314
Clearing and Grubbing Only (1st Review)
3455 N. La Cholla Boulevard - R-1 Zoning

TRANSMITTAL DATE: January 24, 2019

DUE DATE: January 25, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: Zoning has reviewed the clearing and grubbing plan as it relates to the zoning review purview. Zoning has no concerns at this time with regards to clearing and grubbing the site assuming that the PDSD Engineering and Landscape reviewers approve the plan.

As of this review there is no development proposal. The only approval that can be granted at this time is for the surface clearing and grubbing.

02. COMMENT: Zoning will review the clearing and grubbing plan on the next submittal and approve it once the PDSD Engineering and Landscape Reviewer's comments have been addressed and any applicable changes made to the plans. Please address all reviewers' comments, make the necessary changes to the plans and resubmit the plans for review.

03. COMMENT: Include the PDSD stamp in the lower right corner of all plan sheets. The digital copy of the PDSD stamp can be downloaded using the following link; https://www.tucsonaz.gov/pdsd/development-permits the digital stamp can be downloaded in a PDF, JPEG or DWG Format. Look under the "Preparing Your Plans for a Development Package Permit Section - Development Package Stamp.

04. COMMENT: List the PDSD case number DP18-0314 in the lower right corner next to the title block of all plan sheets.


If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Clearing and Grubbing Plan
01/28/2019 ANDREW CONNOR NPPO REVIEW Reqs Change Include the PDSD stamp in the lower right corner of all plan sheets. The digital copy of the PDSD stamp can be downloaded using the following link; https://www.tucsonaz.gov/pdsd/development-permits the digital stamp can be downloaded in a PDF, JPEG or DWG Format. Look under the "Preparing Your Plans for a Development Package Permit Section - Development Package Stamp.

List the PDSD case number DP18-0314 in the lower right corner next to the title block of all plan sheets.
Ensure that all Engineering comments are addressed.
01/29/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP18-0314

1) Per City of Tucson Administrative Manual (AM) section 2-06.4.7.B add the required hold harmless note and drainage will remain it is natural state note to the submitted plans
2) Add additional narrative to the swppp manual indicating the corresponding plan set that is being referenced.
3) Add to the plans the swppp manual and permit number under which the project will operate
4) Provide a project location map according to City of Tucson (COT) Administrative Manual section 2-04.4.4
5) Per AM section 2-06.4.8 show on plans existing grades and contours including all areas within 50' of the proposed project
6) A floodplain use permit will be required for this project since it encroaches into a mapped floodplain. This will be done when the revisions to the project are complete

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007

Final Status

Task End Date Reviewer's Name Type of Review Description
02/15/2019 AVAUGHN1 OUT TO CUSTOMER Completed