Permit Number: DP18-0302
Parcel: 11006009A

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - DP18-0302
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/29/2020 SBEASLE1 ZONING REVIEW Reqs Change (Review comments are from the Okay to Submit, 06/26/20)


PDSD TRANSMITTAL
FROM: Steve Shields, Section Manager

PROJECT: Foothills Storage, DP18-0302
Development Package (Revision #1)

TRANSMITTAL DATE: April 20, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above.

1. 2-06.3.5 - The required space in the lower right quadrant of each sheet for the approval stamp has been removed from SP2.0. Provide the required space.

2. 2-06.3.12 - The sheet numbers provided in the "SHEET INDEX" do not match the sheet numbers on the sheets. The 2nd sheet listed in the "SHEET INDEX" is listed as SP-1 but on the plan set it is listed as SP1.0. The 3rd sheet listed in the "SHEET INDEX" is listed as
SP-2 but on the plan set it is listed as SP2.0.

3. 2-06.4.3 - The required development package case number, DP18-0308, and the required rezoning case number have been removed from sheets SP1.0 & SP22.0

4. 2-06.4.9.H.5 - It does not appear that there is sufficient maneuverability into the eastern most parking space shown in the southeast corner of the site.

5. 2-06.4.9.H.5.a - There are no dimensions shown for the proposed vehicle parking spaces shown along the west and south property lines. Provide a fully dimensioned parking layout that addresses all applicable dimensions shown on UDC figure 7.4.6-A and table 7.4.6-1.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
06/29/2020 SBEASLE1 ENGINEERING REVIEW Reqs Change (Review comments are from the Okay to Submit, 06/29/20)

DP18-0302
1) Provide dimensions for the new proposed angular parking. Reference City of Tucson Unified Development Code Figure 7.4.6-A

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
06/30/2020 GDAURIA1 FIRE REVIEW Completed
07/28/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change REVISION PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required

PROJECT DESCRIPTION: SITE/GRADING/SWPPP - Foothills Storage.
PERMIT: DP18-0302
Project Manager: Nicholas.Ross@TucsonAz.gov
FEE BALANCE: $0 (zero) Thank you for the payment

VIEW the review comments and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

After the corrections are made, please name your Revision #1, 2nd submittal documents accordingly, for example: REV-1_2_Plan_Set.

YOUR NEXT STEPS: Submit documents to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd
** IMPORTANT: Select the box "Development Package..." **
1) Comment Response Letter (your response to the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov
07/28/2020 ANDREW CONNOR LANDSCAPE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/28/2020 SBEASLE1 OUT TO CUSTOMER Completed