Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP18-0302
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/26/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: Foothills Storage DP18-0302 Development Package (Revision #1) TRANSMITTAL DATE: April 20, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). The review comments include the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above. 1. 2-06.3.5 - The required space in the lower right quadrant of each sheet for the approval stamp has been removed from SP2.0. Provide the required space. 2. 2-06.3.12 - The sheet numbers provided in the "SHEET INDEX" do not match the sheet numbers on the sheets. The 2nd sheet listed in the "SHEET INDEX" is listed as SP-1 but on the plan set it is listed as SP1.0. The 3rd sheet listed in the "SHEET INDEX" is listed as SP-2 but on the plan set it is listed as SP2.0. 3. 2-06.4.3 - The required development package case number, DP18-0308, and the required rezoning case number have been removed from sheets SP1.0 & SP22.0 4. 2-06.4.9.H.5 - It does not appear that there is sufficient maneuverability into the eastern most parking space shown in the southeast corner of the site. 5. 2-06.4.9.H.5.a - There are no dimensions shown for the proposed vehicle parking spaces shown along the west and south property lines. Provide a fully dimensioned parking layout that addresses all applicable dimensions shown on UDC figure 7.4.6-A and table 7.4.6-1. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 06/29/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0302 1) Provide dimensions for the new proposed angular parking. Reference City of Tucson Unified Development Code Figure 7.4.6-A John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 06/29/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Passed |