Permit Number: DP18-0302
Parcel: 11006009A

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP18-0302
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/18/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/20/2020 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: Foothills Storage
DP18-0302
Development Package (Revision #1)

TRANSMITTAL DATE: April 20, 2020

The development package has been reviewed by the Zoning Review Section but cannot be accepted for review:

1. The drawings sheets provided do not appear to be from the approved development package (DP) set. The last approved set had 16 sheet and this set only has 12sheets.
2. The provided revision letter references sheets SP1.0, SP1.2 & E1.0. These sheets were not provided with the revision.
3. All sheets of the last approved DP set that have the parking layout shown on them will need to be revised.
4. Provide the proposed "A Parking angle" for both sets of angled parking on the plan see UDC Table 7.4.6-1
5. The provided "C Space depth" provided for the western angled parking does not meet the requirements of UDC Table 7.4.6-1 for 60 degree parking.
6. Provide the "E Curb length" dimension for both sets of angled parking.


If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/20/2020 SSHIELD1 ENGINEERING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: Foothills Storage
DP18-0302
Development Package (Revision #1)

TRANSMITTAL DATE: April 20, 2020

The development package has been reviewed by the Zoning Review Section but cannot be accepted for review:

1. The drawings sheets provided do not appear to be from the approved development package (DP) set. The last approved set had 16 sheet and this set only has 12sheets.
2. The provided revision letter references sheets SP1.0, SP1.2 & E1.0. These sheets were not provided with the revision.
3. All sheets of the last approved DP set that have the parking layout shown on them will need to be revised.
4. Provide the proposed "A Parking angle" for both sets of angled parking on the plan see UDC Table 7.4.6-1
5. The provided "C Space depth" provided for the western angled parking does not meet the requirements of UDC Table 7.4.6-1 for 60 degree parking.
6. Provide the "E Curb length" dimension for both sets of angled parking.


If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
04/21/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change REVISION PLAN DENIED FOR REVIEW AND RETURNED FOR CORRECTIONS
- A resubmittal is required

Project Description: SITE/GRADING/SWPPP - Foothills Storage.

Permit: DP18-0302

Manager: Nicholas.Ross@Tucsonaz.gov

View the Zoning and Engineering reviewer's comments in "Dev Pkg - OK to Submit" on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

After the corrections are made, please name your Revision #1 as a first submittal again, for example: REV-1_Plan_Set.

YOUR NEXT STEPS: Submit the following items to the Filedrop- https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue
(the physical office) is closed to the public?until further notice.
In the meantime, our staff is working remotely from home.
All communications are by telephone or email.

CONTACT US: To speak with a staff member on the telephone, please sign into the Virtual Zoning Counter: https://www.tucsonaz.gov/pdsd/virtual-walk-thru.
The queue is open from 8:00 am -12:00 noon, Monday-Friday.
It’s better to sign in closer to 8 than 12 noon.
This is similar to the City’s in-person counter.
The difference is after you sign up, we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov