Permit Number: DP18-0302
Parcel: 11006009A

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP18-0302
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/13/2018 SBEASLE1 START PLANS SUBMITTED Completed
12/13/2018 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Needs Review 12/11/18

This project will require review by Pima County Addressing. Please send me your submittal set to determine the review fees. Thank you

Nicholas Jordan, Addressing Specialist
Pima County Development Services Department
201 N Stone AV
Tucson, AZ 85701
(520) 724-9623
12/13/2018 SBEASLE1 WWM REVIEW Passed 12/12/18

Your project requires a Preliminary Sewer Layout submittal for the connection to the public sewer line which requires the installation of a new manhole (Please see below for the section of the Standards that require the manhole). You will also need a small activity permit from RWRD for the installation of the manhole.

5.3.2 Connections to Public Sewer
Service Laterals shall connect to the Public Sewer by method of a direct connection to the sewer line or in some cases, to a manhole. The following describes the criteria for determining the required method of connection.
HCS connections, 4 inches in diameter, shall connect to Public Sewer lines, less than or equal to 12 inches in diameter, by a direct connection per S.D. RWRD-401.
HCS connections into manholes shall be avoided where possible. Non perpendicular HCS alignments may be permitted to avoid connections into manholes. For non-perpendicular HCS alignments, the connection to the sewer
line shall be located within the projected property lines of the lot it is servicing. If the connection of an HCS into a manhole cannot be avoided, it may be allowed for the following types of manholes:
A terminal manhole with no potential for a future sewer line extension (a maximum of 3 HCS connections); or
A manhole located within a knuckle intersection (a maximum of 2 HCS connections).

Service Laterals and private sewer systems shall connect into a Public Sewer manhole in any of the following cases:
The internal diameter of the Service Lateral is equal to or one nominal size smaller than the diameter of the Public Sewer line (excludes a 4 inch HCS connection to an existing 6 inch diameter Public Sewer line);
The nominal size of the Service Lateral is greater than 4 inches in diameter, regardless of the size of the Public Sewer line; or
The Public Sewer line is 15 inches in diameter or greater, per Subsection 5.3.4.

Laith Alshami, P.E.
Site Project Manager
Development Services
201 N Stone Avenue., 1st floor
Tucson, AZ 85701
Laith.alshami@pima.gov
12/14/2018 ALEXANDRA HINES ZONING REVIEW Needs Review
12/17/2018 JOHN VAN WINKLE ENGINEERING REVIEW Needs Review