Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP18-0302
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/13/2018 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 12/13/2018 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Needs Review | 12/11/18 This project will require review by Pima County Addressing. Please send me your submittal set to determine the review fees. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV Tucson, AZ 85701 (520) 724-9623 |
| 12/13/2018 | SBEASLE1 | WWM | REVIEW | Passed | 12/12/18 Your project requires a Preliminary Sewer Layout submittal for the connection to the public sewer line which requires the installation of a new manhole (Please see below for the section of the Standards that require the manhole). You will also need a small activity permit from RWRD for the installation of the manhole. 5.3.2 Connections to Public Sewer Service Laterals shall connect to the Public Sewer by method of a direct connection to the sewer line or in some cases, to a manhole. The following describes the criteria for determining the required method of connection. HCS connections, 4 inches in diameter, shall connect to Public Sewer lines, less than or equal to 12 inches in diameter, by a direct connection per S.D. RWRD-401. HCS connections into manholes shall be avoided where possible. Non perpendicular HCS alignments may be permitted to avoid connections into manholes. For non-perpendicular HCS alignments, the connection to the sewer line shall be located within the projected property lines of the lot it is servicing. If the connection of an HCS into a manhole cannot be avoided, it may be allowed for the following types of manholes: A terminal manhole with no potential for a future sewer line extension (a maximum of 3 HCS connections); or A manhole located within a knuckle intersection (a maximum of 2 HCS connections). Service Laterals and private sewer systems shall connect into a Public Sewer manhole in any of the following cases: The internal diameter of the Service Lateral is equal to or one nominal size smaller than the diameter of the Public Sewer line (excludes a 4 inch HCS connection to an existing 6 inch diameter Public Sewer line); The nominal size of the Service Lateral is greater than 4 inches in diameter, regardless of the size of the Public Sewer line; or The Public Sewer line is 15 inches in diameter or greater, per Subsection 5.3.4. Laith Alshami, P.E. Site Project Manager Development Services 201 N Stone Avenue., 1st floor Tucson, AZ 85701 Laith.alshami@pima.gov |
| 12/14/2018 | ALEXANDRA HINES | ZONING | REVIEW | Needs Review | |
| 12/17/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Needs Review |