Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP18-0278
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/23/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/23/2021 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | |
| 08/23/2021 | SBEASLE1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | |
| 08/23/2021 | SBEASLE1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | |
| 08/24/2021 | ALEXANDRA HINES | DESIGN PROFESSIONAL | REVIEW | Reqs Change | 1. Provide neighborhood meeting attendants sign-in list. No AVP needed. No PMP needed if one story residences. Is the proposed height 10 ft per sheet 1 general notes? Alexandra Hines alexandra.hines@tucsonaz.gov |
| 09/15/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Revise the site drawing to include the following existing utility information: a. The location of public water lines and fire hydrants. b. The location and size of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. Note: the existing public sewer does not extend North of the alley. c. The existing and proposed points of connection to the existing public sewer. d. If water mains and sewers are not located on or adjacent to the tract, indicate the direction, distance to, and sizes of those nearest the property. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018. 2. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. 3. For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009. |
| 09/16/2021 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | (The ATTACHED PDF mentioned below can be viewed in the "Documents" section of PRO, titled: "Pima Co Addressing Review Comments") Email from: <Addressing@pima.gov> To: CDRC Tue 9/14/2021 12:58 PM Tenative plat, 1st submittal, 1048 N 2ND AVE, DP18-0278 is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 09/16/2021 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 09/16/2021 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | Email from: Howard.Dutt@TucsonAz.gov To: CDRC Thu 9/16/2021 7:56 AM No existing or proposed Tucson Parks and Recreation facilities are affected by this Tentative Plat. Howard B. Dutt, RLA Landscape Architect Tucson Parks and Recreation (520) 631-2030 |
| 09/17/2021 | FRANK PODGORSKI | HPZ ADVISORY BOARD | HPZ ADVISORY BOARD DATE | Needs Review | Property is a contributing resource to the West University Historic Preservation Zone (WUHZAB) and modifications to the site require review. Plans indicate that a 5' block wall will be installed. This element has not been reviewed or approved. Plans for the fence and any other physical changes to the site should be submitted for Historic review. |
| 09/22/2021 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
| 09/27/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David Stiffey To: CDRC Mon 9/27/2021 7:24 AM Approved. No Comments. |
| 10/07/2021 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | DP18-0278, 1048 N 2nd Av, 1st Review October 7, 2021 Substantial zoning review will not be completed until the following comment is addressed. 1. Per UDC Table 3.2-1 PUBLIC NOTICE AND PROCEDURAL REQUIREMENTS, FLD Subdivision Plat or Site Plan, a Neighborhood Meeting is required. Per UDC Article 3.2.2.C.1. and 8.3.7.P.1.b The meeting shall occur not more than 60 days prior to the date of the submittal of the application. Provide documentation that the neighborhood meeting has bee held within 60 days of your submittal. The first submittal of this application was received on 10/11/18, without a neighborhood meeting already held. That submittal was denied. The second submittal was received 7/12/19, without documentation of the neighborhood meeting which was held on 11/2/18. This meeting was more than 60 days prior to the second submittal and is not valid. A new neighbohoord meeting must be held. Elisa Hamblin, AICP Site Review Section Manager Elisa.Hamblin@tucsonaz.gov |
| 10/14/2021 | SBEASLE1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | Email from: TEPDEVREV@tep.com To: CDRC Mon 10/11/2021 5:52 PM Tucson Electric Power Co. (TEP) has reviewed the plans submitted on August 23rd , 2021, and has no objections at this time. If revisions are needed to the current design - additional easements are required for TEP facilities. They will need to be obtained by separate instrument. Tucson Electric Power Co. Land Resources Department Attn: Courtney Tejedas |
| 11/02/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Clearly identify the functional use of the "functional open space." |
| 11/03/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | email from: COTDSDPermits to: Rene Flores Wed 11/3/2021 10:35 AM Returned for Corrections: DP18-0278 DESCRIPTION: Tentative Plat/FLD - 1048 N 2nd Avenue. Fee Balance: $0 (zero) Thank you for the payment in November 2020. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to REQUIRES CHANGE comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your SECOND submittal documents according to this example: 2_Comment Response Letter FILEDROP for Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Thank you. Sharon Beasley, Building Permit Specialist City of Tucson, Planning and Development Services Email: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |