Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP18-0254
Parcel: 140400620

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP18-0254
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/16/2018 KELLY LEE START PLANS SUBMITTED Completed
10/16/2018 KLEE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed From: Nicholas Jordan <Nicholas.Jordan@pima.gov> on behalf of Addressing
<Addressing@pima.gov>
Sent: Friday, October 12, 2018 8:50 AM
To: Rick Bright
Cc: DSD_CDRC@TUCSONAZ.GOV
Subject: RE: Development Plan Submittal
Good morning,
This project will not require review by Pima County Addressing.
Feel free to contact me if you have any questions.
Nicholas Jordan
Addressing Specialist
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
10/16/2018 KLEE1 WWM REVIEW Passed From: Site <Site@pima.gov>
Sent: Friday, October 12, 2018 8:51 AM
To: Rick Bright
Subject: RE: Development Plan Submittal
Does not need review from RWRD but since it is septic you need to apply for a Septic Permit and submit
to buildingsafetyadmin@pima.gov
See submittal requirements at http://webcms.pima.gov/cms/one.aspx?portalId=169&pageId=63828
Best regards,
David Takaki
Site Review Project Manager
Pima County Development Services Dep
520-724-9556
10/19/2018 JOHN VAN WINKLE ENGINEERING REVIEW Denied DP18-0254 (ok to submit)

1) Provide grading/cut fill quantities on plans
2) Project site is over 1 acre and located in a critical basin. Provide a Hydrology Report/Statement showing that the existing drainage infrastructure meets the requirements of the City of Tucson (COT) Stormwater Detention/Retention manual and the COT Standards Manual for Drainage Design and Floodplain Management. A 15% reduction in the existing 2,10 and 100 year peak discharges along with 100% retention of the difference between pre and post developed conditions for a 5 year event is required. Reference COT Stormwater Detention/Retention Manual
3) Project is over one acre, provide a Storm Water Pollution Prevention Plan for the proposed development
4) Provide a vehicular use area surface that meets the City of Tucson (COT) Unified Development Code (UDC) section 7.4.6.I
5) These comments are preliminary and are not considered a complete review of the project. A complete review can be conducted when the above information is provided

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
10/19/2018 KELLY LEE ZONING REVIEW Denied Hi Rick:




Please fill out a development package application. The application you uploaded is a permit application.




https://www.tucsonaz.gov/files/pdsd/cdrc/devpkg_application.pdf




Also, please remove the development package stamp when submitting electronically.




Thank you,