Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP18-0251
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/12/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 10/12/2018 | ALEXANDRA HINES | UTILITIES | SOUTHWEST GAS | Passed | Agency notified for information only. |
| 10/12/2018 | ALEXANDRA HINES | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | Agency notified for information only. |
| 10/12/2018 | ALEXANDRA HINES | OTHER AGENCIES | U. S. POST OFFICE | Passed | Agency notified for information only. |
| 10/25/2018 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | See comments from previous workflow. |
| 10/25/2018 | AHINES2 | ZONING HC | REVIEW | Reqs Change | See zoning comments from previous workflow. |
| 10/25/2018 | MASHFOR1 | COT NON-DSD | FIRE | Approved | |
| 11/05/2018 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Reqs Change | November 5, 2018 ACTIVITY NUMBER: DP18-0251 PROJECT NAME: Goodwill Donation Center PROJECT ADDRESS: 455 W River Road PROJECT REVIEWER: Zelin Canchola TDOT Resubmittal Required: The following items must be revised and added to the Development Package 1. Curb and sidewalk required along the property boundaries. 6 foot sidewalk along River Road, 5 feet along Old Oracle. Keep sidewalk within right of way. The connection from River Road to Old oracle shall be at the corner with new standard access ramp. 2. New access ramps required at the two new driveways along Old Oracle Road. 3. 18 foot curb returns required at new driveways. If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov |
| 11/07/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0251 1) Per City of Tucson (COT) Technical Standards Manual (TSM) section 10-01.4.1 show on plans a minimum 6' wide sidewalk along W River Road and a minimum 5' wide sidewalk along N Old Oracle Rd 2) Provide curb along N Old Oracle Rd Av per PAG standard detail 209 3) Sheet 5. Correct overlapping text in detail G and clearance to lowest sign to be 7'. Correct half deleted text in detail F. 4) Drainage statement indicates that the 8500 sf impervious area requires 350 ft3 of water harvesting. Looking at the grading plan, approximately 778 sf of parking area drains into the 9" deep water harvesting basin. While the basin appears to have sufficient capacity for 8500 sf the tributary area of the basin is only 778 sf. The surface area directed towards the basin should be increased or additional inlets and other water harvesting areas should be provided. Revise drainage statement and grading plan as needed 5) Sheet 3. Keynote 16 indicates sidewalk scuppers. It looks like Keynote 17 (not specified) is pointing to the scuppers on the plan. Correct as needed 6) Provide a trash enclosure that meets the dimensional requirements of figure 3B in section 8 of the TSM 7) Show sight visibility triangles at the intersection of N Old Oracle Rd and W River Rd 8) Provide a copy of the Geotechnical Report by Pattison Engineering project 18-144 9) Provide top/bottom spot grades for all proposed water harvesting areas to show that the 6" effective ponding depth is maintained 10) It does not appear that there is sufficient maneuvering space in front of the swing doors into the building if a vehicle is overhanging the entry sidewalk by 2.5'. Reference ICC A117.1 section 404.2.3.2, figure 404.2.3.2(A). Minimum 60" clear from the wall is required John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 11/07/2018 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 November 7, 2018 WR# 6251040 DSD_CDRC@tucsonaz.gov Dear Alexandra, SUBJECT: Goodwill Donation Center - 1st Submittal 455 W River Rd DP18-0251 Tucson Electric Power Company has reviewed and approved the development plan. There are conflicts within the existing facilities. Customer to contact TEP and make an application for any relocation or removal of facilities, this will be billable to the customer. Approved plans are required for temporary power or servie. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Rich Harrington New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8726 Should you have any technical questions, please call the area Designer, Susie Petty @ 917-8741. Sincerely, Beth Shelton Elizabeth "Beth" Shelton Admin Assistant, Design |
| 11/07/2018 | ALEXANDRA HINES | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this development. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 11/08/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Unified Development Code LANDSCAPE PLAN REQUIREMENTS 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The landscape plan will contain the following identification in the lower right corner of each sheet: Any other relevant case numbers for reviews or modifications that affect the site. 7.6.4. LANDSCAPE STANDARDS River Rd. is a Scenic Route. Street landscape borders on property with street frontage on a designated Scenic Route are subject to the standards of Section 5.3.4,Scenic Route Buffer Area. A buffer area in accordance with Section 5.3.4, Scenic Route Buffer Area, is required on property with street frontage on a designated Scenic Route . Landscaping on Adjacent Sites Existing drought tolerant vegetation on adjacentsites must be considered in design to prevent abrupt changes in plant types and to maintain a visual continuity along street frontages. 5.3. SCENIC CORRIDOR ZONE (SCZ) 5.3.4. SCENIC ROUTE BUFFER AREA A. Requirement 1. A buffer area 30 feet wide, adjacent to the MS&R future right-of-way line, is required and shall be preserved and maintained in its natural state; 2. No development or improvements shall occur in a Scenic Route buffer area except as provided in Section 5.3.4.C, Permitted Improvements; (See Figure 5.3-B.) 3. The buffer area shall be restored as closely to its natural state as possible In areas where public safety or the delivery of public services precludes preservation of existing vegetation; and, 4. The buffer area is in lieu of the landscape border required along street frontages under Section 7.6, Landscaping and Screening Standards. Ensure that all Zoning and Engineering comments are addressed Additional comments may apply. |
| 11/09/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Change the notation on sheet 4 of 8 from "BMV is required" to "BWV is required". |
| 11/20/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | We will close out the review, set to return for corrections (RFC) status, and send notification email. For Dp18-0251, a site review is good for 1 year and a grading review is good for 180 days from initial application, 10/5/18. Alexandra Hines, AICP Lead Planner at Planning and Development Services, City of Tucson 201 N Stone Ave 1st Floor, Tucson, AZ 85701 (520) 837-6975 - alexandra.hines@tucsonaz.gov "Erin Harris" <erin@starconsultingaz.com> 11/20/2018 10:07 AM >>> Alex, Thank you for your call yesterday, I am sorry to have missed you. The Owner would like to place the review on indefinite hold at this time. We do not want to lose the review fees that have been paid (unless there is a way to refund them) in case they decided to move forward in the future. Thank you, Erin Harris, P.E. STAR Consulting |
| 11/20/2018 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Needs Review | |
| 11/20/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | Plan Returned for Corrections (RFC) Notice: DP18-0251 Project Description: E SITE/GRADE- GOODWILL DONATION CENTER To see review comments about the plans, please visit https://www.tucsonaz.gov/pro/pdsd/activity_search and enter activity number above. This review has been completed and resubmittal is required. Prepare a Comment Response Letter which tells the reviewers what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd and the plans will re-enter the 20 working day review cycle: 1) Corrected plan set 2) Items requested by review staff Please type the activity number in Project Description or Message of PDSD Filedrop for resubmittal. Please remember to name your files appropriately, for example: second (2nd) submittal, 2_plan_set.pdf 2_response_letter.pdf The balance is $1,614.60. Review fees must be paid prior to 2nd submittal review. Alexandra Hines |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/20/2018 | AHINES2 | OUT TO CUSTOMER | Completed |