Permit Number: DP18-0248
Parcel: 13613001R

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP18-0248
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/16/2018 MARTIN BROWN FIRE REVIEW Approved
10/30/2018 ANDREW CONNOR NPPO REVIEW Approved
10/30/2018 ANDREW CONNOR LANDSCAPE REVIEW Approved
10/31/2018 SSHIELD1 H/C SITE REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: McDonald's @ 9490 E. Golf Links Road
Development Package (1st Review)
DP18-0248

TRANSMITTAL DATE: October 31, 2018

DUE DATE: November 01, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 11, 2019.

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP18-0248, adjacent to the title block on all sheets.

2. 2-06.4.3 - Provide the rezoning case number, C9-72-80, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A.8 - For development package documents provide:

3. 2-06.4.7.A.8.b - Sheet 1, "CALCULATIONS (TOTAL DEVELOPMENT" remove all references to "FLOOR AREA RATIO" from the plan as it is no longer applicable.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.H.5 - As you are re-working the vehicle parking south of the existing building provide a PAAL width dimension from the re-worked parking south to the existing to remain vehicle parking.

5. 2-06.4.9.H.5 - Southeast corner of the drive-thru provide PAAL width dimension from the new curb called out under Key Note 36 to the angled vehicle parking to the east.

6. 2-06.4.9.H.5.a - It appears that the proposed accessible sign may encroach into the 2'-6" vehicle overhang. Provide a dimension from the sign to the front of the wheel stop that demonstrates that the 2'-6" spaces is clear, see UDC Article 7.4.6.H.3.

7. 2-06.4.9.H.5.a - Provide a parking angle for the existing angled vehicle parking shown along the east side of the building.

8. 2-06.4.9.H.5.a - As you are re-working the vehicle parking south of the existing building provide a parking space depth dimension for the re-worked parking.

9. 2-06.4.9.R - The areas highlighted in orange near the northwest corner of the existing building are required to be a sidewalk, physically separated from the vehicle use area, see TSM Section 7-01.4.2 & 7-01.4.3.C.

10. 2-06.4.9.R - Sheet 3 there is a striped area shown along the north side of the proposed van accessible vehicle parking. This striped area gives a false impression of an access aisle and needs to be removed.

11. There are two (2) sidewalk areas, one (1) near the northwest corner of the existing building and one (1) near the southwest corner of the existing building that sheets 3 & 4 do not match, clarify why.

12. Sheet 3 all dimensions and some text are shown as boxes and unreadable.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/31/2018 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: McDonald's @ 9490 E. Golf Links Road
Development Package (1st Review)
DP18-0248

TRANSMITTAL DATE: October 31, 2018

DUE DATE: November 01, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 11, 2019.

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP18-0248, adjacent to the title block on all sheets.

2. 2-06.4.3 - Provide the rezoning case number, C9-72-80, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A.8 - For development package documents provide:

3. 2-06.4.7.A.8.b - Sheet 1, "CALCULATIONS (TOTAL DEVELOPMENT" remove all references to "FLOOR AREA RATIO" from the plan as it is no longer applicable.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.H.5 - As you are re-working the vehicle parking south of the existing building provide a PAAL width dimension from the re-worked parking south to the existing to remain vehicle parking.

5. 2-06.4.9.H.5 - Southeast corner of the drive-thru provide PAAL width dimension from the new curb called out under Key Note 36 to the angled vehicle parking to the east.

6. 2-06.4.9.H.5.a - It appears that the proposed accessible sign may encroach into the 2'-6" vehicle overhang. Provide a dimension from the sign to the front of the wheel stop that demonstrates that the 2'-6" spaces is clear, see UDC Article 7.4.6.H.3.

7. 2-06.4.9.H.5.a - Provide a parking angle for the existing angled vehicle parking shown along the east side of the building.

8. 2-06.4.9.H.5.a - As you are re-working the vehicle parking south of the existing building provide a parking space depth dimension for the re-worked parking.

9. 2-06.4.9.R - The areas highlighted in orange near the northwest corner of the existing building are required to be a sidewalk, physically separated from the vehicle use area, see TSM Section 7-01.4.2 & 7-01.4.3.C.

10. 2-06.4.9.R - Sheet 3 there is a striped area shown along the north side of the proposed van accessible vehicle parking. This striped area gives a false impression of an access aisle and needs to be removed.

11. There are two (2) sidewalk areas, one (1) near the northwest corner of the existing building and one (1) near the southwest corner of the existing building that sheets 3 & 4 do not match, clarify why.

12. Sheet 3 all dimensions and some text are shown as boxes and unreadable.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/31/2018 SSHIELD1 ADA REVIEW Passed
11/01/2018 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Provide the correct dimensions for the sight visibility triangles. Include the SVTs for the intersection of Harrison Road and Golf Links Road. Align the east driveway SVT with the driveway with the driveway curb line. Note that since there is a median in Golf Links Road the east driveway SVT should be 20' X 30'.
2. A floodplain use permit is required for the site work within the floodplain area.
3. The printed plans have several locations where the letters are not shown. Please correct and ensure the submitted plans are legible.
4. Make sure all relevant features are dimensioned on the plans.
11/02/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site drawing to include the following existing utility information:
a. The location of water lines and fire hydrants.
b. The location and size of sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number.
c. The point of connection to existing public sewers.
d. Any existing or proposed utility easements
e. The first floor elevation for the building
Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/05/2018 QJONES1 APPROVAL SHELF Completed
11/05/2018 QJONES1 OUT TO CUSTOMER Completed
11/05/2018 QJONES1 REJECT SHELF Completed