Permit Number: DP18-0243
Parcel: 117050090

Address:
434 N 4TH AV

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP18-0243
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2019 SBEASLE1 START PLANS SUBMITTED Completed
10/30/2019 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section
PROJECT: DP18-0243 - Commercial / Food Service
(Caruso"s Restaurant) ADA Restrooms and Awning (DDO Comments Review)
434 N. 4th Avenue - C-3 Zoning

TRANSMITTAL DATE: October 30, 2019
DUE DATE: November 20, 2019
COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the C-3 zone (UDC 4.8.6). A "Food Service Use" is a permitted use in this zone per (Table 4.8-4).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed building wall (UDC 6.4.5.C.1.a - Established Areas).

Prior to approval of DP18-0243 and associated building plans for the proposed Awning and ADA modifications, a Design Development Option Application will have to be processed and approved through PDSD.

The existing front street building setback is non-conforming per the current UDC regulations at 16'-9".

The proposed awning is 10'-2" in height and the proposed setback is 1 foot from the 4th Avenue street property line.

The proposed Awning along 4th Avenue does not meet the minimum front Street Perimeter setback of 20 feet from the property line and requires approval for a setback modification through the Design Development Option process.

Assure that the DDO application case number, date of approval and modification requested and approved are listed as a general note on the DP sheet. In addition list the DDO application case number next to the title block.

Revise the DP case number next to the title block to
" DP18-0243 ". (Remove the dash between the numbers 2
and 4.)

***Note: Building elevations were not included in the DP package. Staff reviewing the DDO application will be requiring building elevations to be submitted for the DDO process. Zoning has provided DDO comments based on the information provided on the DP plan but cannot verify the design or height of the Awning.



If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Plans as noted above
10/31/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change REVISION RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required.
Permit/Activity Number: DP18-0243 Please include this number on all future correspondence.
Project Description: SITE - Caruso's Restaurant, ADA restrooms, new awning for wheelchair lift area.

Fee Balance: $0 (zero). Thank you for the payment.
View the documents and the reviewer's comments: www.tucsonaz.gov/pro
(If information is not available, check back later as data transfers to PRO periodically.)
- Home page, left side, “Activity Search”, enter the Activity Number
- “Permits” section, click on blue tab
- “Documents” section, click on blue icon to the right of each document
- "Reviews" section, click on "Review Details"

Submit the following items to the Filedrop. Before uploading, please enter the Activity Number in the Project Description field.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's “Requires changes” comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 3rd submittal revision documents accordingly, for example: REV-1_3_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2019 SBEASLE1 OUT TO CUSTOMER Completed