Permit Number: DP18-0228
Parcel: 112022100

Address:
3675 N TUCSON BL

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Permit Number - DP18-0228
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change I agree with your response that only lot 13 requires a backwater valve but lots 7 and 8 are also marked as needing backwater valves. [Initial comment: Where the finished floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Indicate which lots will require the installation of a backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.]
01/07/2019 ANDREW CONNOR LANDSCAPE REVIEW Approved
01/07/2019 LOREN MAKUS ENGINEERING REVIEW Reqs Change Provide the activity number for the TSMR on each sheet. Include a note indicating the TSMR has been approved and list any conditions of approval.
I can review this "over the counter" once the resubmittal has been accepted. Please let me know when you have been notified the corrected package has been received.
01/08/2019 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP
Principal Planner
PDSD Zoning Review Section

PROJECT: Las Cabañas (formerly Los Sueños) FLD - Lots 1-15 and Common Areas A, B, and C
Development Package (2nd Review) - 3645 N. Tucson Boulevard
DP18-0228 - R-1 Zoning

TRANSMITTAL DATE: January 8, 2019
DUE DATE: January 7, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is September 12, 2019.

1. Previous comment 11. The proposed street design will have to be approved through a TSMR request for modifications. In addition the proposed design may not be acceptable to TDOT for dedication as a Public Street. The proposed street may have to be a private street/common area. The DP cannot be approved until the TSMR request has been approved. Provide case number and documentation with next submittal.

2. Previous comment 13. Revise the building setbacks on the cover sheet to clearly state the required building setbacks for the dwelling and garage/carport for lots 7, 8 and 9. Lot 7 and 8 are fronting on three street and lot 9 fronts on 2 streets. Revise as required.

For the dwelling, interior street building setbacks are based on the greatest of 21 feet or the height from the nearest edge of travel lane. Garage and carport building setbacks for this project must be 19 feet from back of sidewalk.

Request for Director's Decision Letter must be approved prior to approval of the development package. Review is pending.

3. Previous comment 14. A four-foot-wide sidewalk along the south side of Street C and along the west side of Street B must be provided. The TSMR must be approved prior to approval of the development package. Provide case number and documentation with next submittal

4. Previous comment 17. If applicable. Add a general note that states that free standing monument signage will be permitted under separate permit. The submitted transmittal comments state this was added, but could not be found as a general note on the cover sheet.

5. Previous comment 27. Three copies of the Covenants, Conditions, and Restrictions (CC&Rs) regarding the homeowner's association's responsibility for the ownership and maintenance of commonly-owned property will be required to be submitted with the final plat.

6. Previous comment 28. Two copies of the protective covenants or common use agreements for any shared areas being established by easements over individually-owned property will be required to be submitted with the final plat.

7. Comment: Correct general notes 27 and 34 on the cover sheet. Duplication and incorrect ordinance reference is found.

If you have any questions about this transmittal, please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/08/2019 EHAMBLI1 ZONING HC REVIEW Reqs Change See Zoning comments.
01/08/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Plans Returned for Corrections (RFC) Notice: DP18-0228
Project Description: E TENTATIVE PLAT/GRADE/SWPPP- LAS CABANAS FLD (FORMERLY LOS SUENOS)

The review has been completed and a resubmittal is required.
To see review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)

Prepare a Comment Response Letter detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made to the plans, go to the PDSD Filedrop web page. Please enter the Activity Number in the “Project Description” field and name the files as directed, for example, 3rd submittal: “3_Plan_Set.pdf”.
Submit the following items to the PDSD Filedrop at www.tucsonaz.gov/file-upload-pdsd.
The plans will then re-enter a 20-working-day review cycle.­
1) Comment Response Letter
2) Corrected plan set with all documents
3) Items requested by review staff
The current fee balance is $82.50 (see image below). Review fees must be paid prior to the next review. Please include your Activity Number on the check stub.

Elisa Hamblin, copied, is the Project Manager to contact with any questions, email: Elisa.Hamblin@TucsonAz.gov or phone (520) 837-4966. Thank you.

Sharon Beasley
City of Tucson
Planning and Development Services
201 N. Stone Avenue, First Floor­
Tucson, AZ 85701
12/07/2018 SBEASLE1 START PLANS SUBMITTED Completed
12/11/2018 MASHFOR1 COT NON-DSD FIRE Approved
12/26/2018 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved DP18-0228: Las Cabanas/Los Suenos / 2nd SUBMITTAL is Approved by Pima County Addressing.
Thank you,
Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV - 4th Floor
Tucson, AZ 85701
(520) 724-7570

Final Status

Task End Date Reviewer's Name Type of Review Description
01/08/2019 SBEASLE1 OUT TO CUSTOMER Completed