Review Date Reviewer's Name Type of Review Description Status Comments
01/03/2019 NICHOLAS ROSS ZONING REVIEW Approved
01/03/2019 ANDREW CONNOR NPPO REVIEW Approved
01/04/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP18-0213

1) Add reference to geotechnical report on sheet 1
2) Add DP18-0213 to all sheets
3) Geotechnical report section 3.6 recommends that the top of embankments be provided with a drainage ditch in addition to an intermediate drainage feature if the elevation change is greater than 15'. Details X/8 and R/8 show one v-ditch approximately halfway up the embankment. Clarify if this meets the intent of the geotechnical report. Also provide the height at which the v-ditches occur. It is not shown on the grading plan at which elevation the proposed drainage channels will be located
4) Detail K/6 says "SEE GENERAL NOTE No." Update to show which general note is to be referenced
5) An expedited review can occur once the above comments have been addressed and updated plans with a response letter have been submitted. Email to Schedule

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
01/04/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change