Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP18-0212
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Tres Pueblos Este - Grading Plan Development Package (1st Review) DP18-0212 - Related to DP18-0107 TRANSMITTAL DATE: October 3. 2018 DUE DATE: October 11, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 27, 2019. 2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet. 1. COMMENT: The title block on the grading plan appears to be for PIA when submitting to TDOT. Revise the title block to match the title block of the tentative plat for this development. 2. COMMENT: Provide the development package case number, DP18-0212, adjacent to the title block on each sheet. Also reference the tentative plat case number Dp18-0107 next to the title block of all plan sheets. 3. COMMENT: Assure that any changes that are made to the grading plan or tentative plat affecting either plan are made accordingly. Zoning will approve the grading plan once the PDSD Engineering and Landscape reviewers have approved the plans. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Grading package |
| 10/10/2018 | ANDREW CONNOR | NPPO | REVIEW | Reqs Change | Ensure that any changes made to the grading plan or tentative plat affecting either plan are made accordingly. Landscape will approve the grading plan once the PDSD Engineering have approved the plans. |
| 10/11/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0212 1) All sheets. Title block shows references City of Tucson Department of Transportation. Title block appears to be incorrect. Provide an updated title block 2) Per City of Tucson Stormwater Detention/Retention Manual section 3.4.2 provide a grade control marker for each proposed basin. On the plans please also provide the coordinates of the grade control marker so that they can be easily located in the future 3) Sheet 7 detail N. Retaining wall detail does not match the detail shown in the page 7 of Wright Engineers geotechnical report Project No. 180269. Clarify and update 4) Per City of Tucson Administrative Manual (AM) section 2-06.4.7.B add the required hold harmless note John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 10/12/2018 | NROSS1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Plan Returned for Corrections (RFC) Notice: DP18-0212 Project Description: Tres Pueblos Este To see review comments about the plans, please visit https://www.tucsonaz.gov/pro/pdsd/activity_search and enter activity number above. This review has been completed and resubmittal is required. Prepare a Comment Response Letter which tells the reviewers what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd and the plans will re-enter the 20 working day review cycle: 1) Corrected plan set 2) Items requested by review staff Please type the activity number in Project Description or Message of PDSD Filedrop for resubmittal. Please remember to name your files appropriately, for example: second (2nd) submittal, 2_plan_set.pdf 2_response_letter.pdf Review fees must be paid prior to resubmittal review. Nick Ross Lead Planner Planning & Development Services City of Tucson |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/12/2018 | NROSS1 | APPROVAL SHELF | Completed |
| 10/12/2018 | NROSS1 | OUT TO CUSTOMER | Completed |
| 10/12/2018 | NROSS1 | REJECT SHELF | Completed |