Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP18-0211
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 11/06/2018 | MARTIN BROWN | FIRE | REVIEW | Reqs Change | All parts of the building must be within 600' of a fire hydrant. Please provide an additional hydrant and locate on plans. |
| 11/27/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 11/27/2018 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | November 27, 2018 Alexandra Hines Lead Planner City of Tucson Public Works Buildings – 201 North Stone Avenue Tucson, AZ. 85701 RE: DP18-0211 Rincon Country West RV Resort / 2nd Submittal, Received November 2, 2018 Dear Ms. Hines, Thank you for the opportunity to comment on DP18-0211, Rincon Country West RV Resort; 2nd Submittal, a development package application for an approximately 0.24 acre site, located approximately 0.25 miles southeast of the intersection of South Mission Road and West Via Ingresso. The land use is recreational vehicle (RV), with the proposed development being a wood shop building. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority is satisfied with the 2nd submittal of this project and has no additional comments to submit. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, Senior Airport Planner cc file |
| 11/29/2018 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 11/29/2018 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 11/30/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 12/03/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Comment not addressed. [Initial comment: Revise the site drawing to include the pipe diameter of the sanitary sewers and the invert and rim elevations of all manholes and cleanouts. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012.] 2. Comment not addressed. [Initial comment: Where the finished floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.] |
| 12/04/2018 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | 12/04/18 Plans Returned for Corrections (RFC) Notice: DP18-0211 Project Description: E SITE/GRADING - RINCON COUNTRY WEST RV RESORT The review has been completed and a resubmittal is required. To see review comments about the plans, visit PRO at www.tucsonaz.gov/PRO, then search by activity number. (If new comments aren't shown yet, please check back later as data flows to PRO at periodic intervals throughout the day.) Prepare a Comment Response Letter for the reviewers detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made to the plans, please submit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. The plans will then re-enter the 20 working day review cycle. 1) Comment Response Letter 2) Corrected plan set 3) Items requested by review staff Please type the activity number in the Project Description and name the files as described on the PDSD Filedrop web page. The current fee balance is $0 (zero). Thank you. Sharon Beasley City of Tucson Planning and Development Svcs. Dept. 201 N. Stone Ave, 1st Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/04/2018 | SBEASLE1 | OUT TO CUSTOMER | Completed |