Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP18-0199
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2018 | KELLY LEE | START | PLANS SUBMITTED | Completed | |
| 08/16/2018 | KLEE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Passed | From: Nicholas Jordan <Nicholas.Jordan@pima.gov> On Behalf Of Addressing Sent: Tuesday, August 14, 2018 10:18 AM To: Tim Loftis <timi@dormanconstruction.com> Cc: DSD_CDRC@TUCSONAZ.GOV Subject: RE: City of Tucson New Devel. Package Good morning, The project at 5801 E Grant RD will not require review by Pima County Addressing. Thank you Nicholas Jordan Addressing Specialist Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
| 08/16/2018 | NROSS1 | ZONING | REVIEW | Reqs Change | PDSD Zoning Review FROM: Nick Ross PDSD Zoning Review Section PROJECT: OK to Submit Address: 5801 E. Grant Road Zoning: R-2 Existing Use: Cemetery Proposed Use: Mausoleum Addition TRANSMITTAL DATE: August 16, 2018, 1. COMMENT: Submittal of a full development package in compliance with AM 2-06 is required. Please review the draft minor site review checklist. 2. COMMENT: On Sheet 2, provide the last approved site plan or revise the overall site to show access, parking, buildings, and all calculations. 3. COMMENT: Remove floorplan/foundation/elevations from development package. These items are part of the building plans. 4. COMMENT: On Sheet 3, show the entire area including the existing building to the south on the enlarged site plan. 5. COMMENT: Ensure that you are parking counts, expansion calculations and dimensional standards are provided on your site plan. See example site plan provided by email. 6. COMMENT: These comments are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, Contact Nick Ross at (520) 837-4029 or by email Nicholas.Ross@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov |
| 08/16/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Denied | DP18-0199 1) Refer to Zoning comments for the review of the application submittal requirements 2) Provide complete dimensions for all proposed walkways, sidewalks and ramps and parking spaces 3) Provide grading cut/fill quantities 4) These are preliminary review comments and are required to be address prior to a complete project review John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 08/16/2018 | KLEE1 | WWM | REVIEW | Passed | From: Sewer <Sewer@pima.gov> Date: August 15, 2018 at 10:33:10 AM PDT To: Tim Loftis <timi@dormanconstruction.com> Cc: Kelly Lee <Kelly.Lee@tucsonaz.gov>, Gerry Koziol <Gerry.Koziol@pima.gov>, Chris Anderson <Chris.Anderson@pima.gov> Subject: RE: City of Tucson New Devel. Package Good morning Tim, Based off your description below regarding the proposed development and no new bcs connection shown on the plan sheets provided, the Development Plan Package does not require a preliminary sewer layout review and approval from Pima County Development Services. Note: that during the building permit submittal to the City of Tucson the existing bcs connection may be reviewed for verification of an existing connection permit and capacity requirement. Please submit for review to sewer@pima.gov to the attention of Gerry Koziol, at that point in time. Thanks, Joseph Joseph Godoy Site Division Manager Pima County Development Services 201 N. Stone Ave Tucson, AZ 85701 joseph.godoy@pima.gov (520) 724-6756 |