Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP18-0198
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/06/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0198 1) Per City of Tucson Administrative Manual (AM) section 2-06.4.7.B add the required hold harmless note 2) Per City of Tucson Stormwater Detention/Retention Manual section 3.4.2 provide a grade control marker for the proposed basin. On the plans please also provide the coordinates of the grade control marker so that they can be easily located in the future 3) Detail A/C5 shows the perimeter sidewalk sloping away from the water harvesting area. On sheet 3, immediately adjacent to the location of detail A/C5 the sidewalk is shown sloping towards the water harvesting area. Confirm if this is intentional and modify the standard detail if needed 4) PAG standard detail 204 shows that the bottom of the scupper is to be 1" above grade. Provided spot grades indicate that the bottom of the scupper is below grade on both sides. Provide additional spot grades to show that the scuppers directed towards the proposed retention basin drain properly. 5) Engineering can conduct an expedited electronic review once all outstanding department review comments have been addressed, the revised plans are resubmitted and a new work flow has been opened. Call or email to schedule. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 09/06/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Menlo Park Apartments - Grading plan for Pool and Clubhouse Area. Development Package (1st Review) - Related to DP18-0084 DP18-0198 TRANSMITTAL DATE: September 6, 2018 DUE DATE: September 18, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 15, 2019. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.3.6 - Provide a blank three-inch by five-inch block in the lower right corner of the plan adjacent to the title block on the first sheet of the development package for use by Pima County Addressing. 1. COMMENT: 2-06.3.5 - Remove the Development Package PDSD approval stamp on all sheets. Reserve a three-inch by five-inch space in the lower right quadrant of each sheet for an approval stamp. The approval stamp will be applied electronically. As of this zoning review of the grading plan the DP18-0084 has been approved but has not been issued. The grading plan cannot be issued until the DP is issued. The applicant of the DP application must pick up the approved DP before the grading plan is issued or at the same time. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/18/2018 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 09/18/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Plan Returned for Corrections Notice: DP18-0198Project Description: E GRADE - MENLO PARK APT- NEW POOL & COMM. CENTER This review has been completed and resubmittal is required. To see reviewer's comments about your plans, please visit https://www.tucsonaz.gov/pro/pdsd/activity_search. You will need to enter the activity number shown above to see comments about the plan. Prepare a Comment Response Letter which tells the reviewers what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd and the plans will re-enter the 20 working day review cycle:1) Corrected plan set2) Items requested by review staff Please remember to name your files appropriately, for example: second (2nd) submittal,2_plan_set.pdf2_response_letter.pdf Alexandra Hines, AICP Lead Planner at Planning and Development Services, City of Tucson 201 N Stone Ave 1st Floor, Tucson, AZ 85701 (520) 837-6975 - alexandra.hines@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/18/2018 | AHINES2 | OUT TO CUSTOMER | Completed |