| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2018 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 08/06/2018 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/13/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0169 1) Sheet 1. Provided scale shows 1" = 150', scale stated is 1' = 100' 2) FFE of proposed building in DP18-0169 is shown as 37.67, in the Reference DP14-0167 it is shown as 38.67. Clarify which FFE is correct 3) Sheet 2, Keynote 8. "Begin" appears to be assigned to the incorrect keynote 8; there is a keynote 8 to the east where the curb removal should begin 4) Show on plans that any roof drains (downspouts) scupper underneath sidewalks or pedestrian walkways. Reference COT Technical Standard (TSM) 7-01.4.1.E 5) Provide dimensions for the width of sidewalks around proposed building. Verify that the minimum width of 4' is maintained as vehicles can overhang by 2.5' since wheel stops are not provided John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 08/16/2018 | KELLY LEE | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Ryan: This review has been completed and resubmittal is required. Please resubmit the following items: Prepare a Comment Response Letter which tells the reviewer what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Corrected plan set 2) Items requested by review staff Please remember to name your files appropriately, for example: second (2nd) submittal, 2_plan_set.pdf 2_swppp_report.pdf and the plans will re-enter the review cycle. Thank you, Kelly Lee Lead Planner Planning & Development Services (520) 837-6999 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/17/2018 | KLEE1 | OUT TO CUSTOMER | Completed |