Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP18-0164
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 10/03/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 10/10/2018 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/10/2018 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 10/12/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The point of connection for the new building sewer for the addition to the existing public sewer appears to be between manhole 4360-08 and manhole 4360-07. The rim elevation of manhole 4360-08 is not shown on the drawing but the rim elevation appears to be between 2448 and 2450. The first floor elevation of the addition is not explicitly shown but unless it is one-foot above the rim elevation of manhole 4360-08, a backwater valve will be required for the new building sewer. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson. |
| 10/12/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 10/15/2018 | KELLY LEE | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: Prepare a Comment Response Letter which tells the reviewer what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Corrected plan set 2) Items requested by review staff Please remember to name your files appropriately, for example: second (2nd) submittal, 2_plan_set.pdf 2_swppp_report.pdf and the plans will re-enter the review cycle. Thank you, Kelly Lee Lead Planner Planning & Development Services (520) 837-6999 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/18/2018 | KLEE1 | OUT TO CUSTOMER | Completed |