Permit Number: DP18-0140
Parcel: 13609014B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP18-0140
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2018 ALEXANDRA HINES START PLANS SUBMITTED Completed
06/14/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed Agency notified for information only.
06/14/2018 ALEXANDRA HINES OTHER AGENCIES PIMA ASSN OF GOVTS Passed Agency notified for information only.
06/14/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed June 27, 2018


WR# 6236122


DSD_CDRC@tucsonaz.gov

Dear Alexandra

SUBJECT: Sprung @ Pantano Christian Church
1755 S Houghton Rd
DP18-0140


Tucson Electric Power Company has reviewed and not approved the development plan. It appears there are TEP facilities that are in conflict with existing facilities and will need to be relocated. Please make corrections and resubmit for approval.

There are no facilities shown on the map. There is an easement depicted which should encompass the 3Ø primary cable and transformer. The existing transformer is 500kVA 277/480V. Depending on the needs of the proposed building it may need to be re-sized.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer, Cruz Vega @ 917-8713.


Sincerely,
Beth Shelton
Elizabeth "Beth" Shelton
Admin Assistant Design
06/14/2018 ALEXANDRA HINES OTHER AGENCIES U. S. POST OFFICE Passed Agency notified for information only.
06/14/2018 ALEXANDRA HINES UTILITIES SOUTHWEST GAS Passed Agency notified for information only.
06/20/2018 MARTIN BROWN COT NON-DSD FIRE Approved
07/03/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
07/06/2018 ALEXANDRA HINES COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
07/09/2018 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Site Section Manager

PROJECT: 'Sprung' at Pantano Christin Church - 1755 S. Houghton Road
Development Package (1st Review)
DP18-0140

TRANSMITTAL DATE: July 9, 2018

DUE DATE: July 10, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 12, 2019.

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP18-0140, adjacent to the title block on all sheets.

2. 2-06.4.2.C - The section corners listed on the location map are not correct, section 25 should be on the east and 26 on the west, also section 15 should be 13.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.8 - For development package documents provide:

3. 2-06.4.7.A.8.c - Provide a building square footage expansion calculation on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.H.5 - Sheet 3 there is a PAAL measurement of 23' per UDC Figure 7.4.6-A and Table 7.4.6-1 the minimum width of a PAAL providing access to 90 degree vehicle parking is 24'-0".

5. 2-06.4.9.H.5.a - Based on the most current aerial photos it appears that a reconfiguration of the accessible vehicle parking spaces shown near the southeast corner of the proposed building is proposed. Cleary demonstrate that the requirements of ICC A117.1-2009 section 502.5 for the parking space and access aisles.

6. 2-06.4.9.H.5.a - The last approved site plan shows 633 vehicle parking spaces provided, this plan shows 730, clarify the difference.

7. 2-06.4.9.R - Cleary demonstrate how pedestrian access is provided from the accessible vehicle parking spaces shown near the southeast corner of the proposed building to the sidewalk to the north.

8. 2-06.4.9.R - Per TSM Section 7-01.4.A At least one sidewalk is required to a project from each street on which the project has frontage, unless there is no vehicular access from a street because of a physical barrier. Clearly show the required connects to the streets.

Once the above comments have been addressed Zoning is willing to provide and over-the-counter review. Email to schedule an appointment for this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/09/2018 SSHIELD1 ZONING HC REVIEW Reqs Change See Zoning comments.
07/09/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

7.6.2. APPLICABILITY
The provisions of this section apply to the following:
A. All new development; and,
B. Expansion of existing development, as provided below:
1. Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:
a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.

Verify that expansion calculations cumulatively are not greater than 25%
07/09/2018 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
07/10/2018 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved
07/12/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP18-0140

1) As shown on the development plan, the project encroaches into a riparian area. Provide an Environmental Resource Report and Mitigation Plan. Update drainage report to reflect the proposed encroachment.
2) Provide a copy, for review, of the previously approved grading/drainage plan for the existing development
3) Show on plans that any roof drains (downspouts) scupper underneath sidewalks or pedestrian walkways. Reference TSM section 7-01.4.1.E.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007

4) In the drainage statement, under proposed development, include the parking lot square footage in the description of impervious cover.
07/13/2018 KELLY LEE ZONING-DECISION LETTER REVIEW Reqs Change Plan Returned for Corrections Notice: DP18-0140
This review has been completed and resubmittal is required. Please resubmit the following items to PDSD Filedrop https://www.tucsonaz.gov/file-upload-pdsd

1) Revised Plan Set
2) All items requested by review staff
3) All items needed to approve these plans
Please remember to name your files appropriately, for example:
Example 2 (second submittal):
2_plan_set.pdf
2_soils_report.pdf
Kelly Lee
Lead Planner
Planning & Development Services
(520) 837-6999

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2018 AHINES2 OUT TO CUSTOMER Completed