Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP18-0134
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0134 1) Per City of Tucson Administrative Manual (AM) section 2-06.4.7, add all applicable notes specifically, including but not limited to the Drainage Notes found in section 2-06.4.7.B 2) Per City of Tucson Stormwater Detention/Retention Manual section 3.4.2 provide a grade control marker in the proposed basin. On the plans please also provide the coordinates of the grade control marker so that it can be easily located in the future. 3) Proposed development is over 1 acre in size. A Storm Water Pollution Prevention Plan is required. 4) Proposed development will encroach into a designated riparian area. Per City of Tucson Unified Development Code (UDC) section 5.7, environmental resource report and mitigation plans are required. 5) Sheet 4, Keynote 6. Eastern end of Honor Street just above where CA "C" is written, keynote 6 appears to be misplaced 6) Eastern most rip-rap channel into the proposed basin does not have a defined starting point. Access ramp to basin reduces the width of the rip-rap channel. 7) Sheet 7, Detail F; Review and adjust callouts. For instance "C" lot has the driveway apron misplaced. 8) Sheet 7, Detail J: Provide the dimension of the driveway opening. Clarify if the overall dimension is what is being referenced in detail F. Overall dimension would be 6'+Driveway Opening + 6'. 9) Double check flow lines within lot boundaries shown on sheet 5 against flow lines shown in Detail F on sheet 7. Example lots 2 and 3 along the east wall. 10) Add DP18-0134 to all sheets 11) Provide the approved Tentative Plat project number on all sheets for reference. An approved tentative plat is required prior to development package approval. 12) A flood plain use permit will be issued for the approved development package once outstanding comments have been addressed. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 07/06/2018 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Site Section Manager PROJECT: 1185 N. Riverfront Estates Grading Plan (1st Review) DP18-0134 TRANSMITTAL DATE: July 6, 2018 DUE DATE: July 6, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Zoning has reviewed the grading plan but was not able to find an approved tentative plat/site plan to compare it to. Until this document is approved/provided Zoning cannot approve the grading plan. 2. Until all other PDSD review agencies have approved the grading plan Zoning cannot approve. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov |
| 07/06/2018 | ANDREW CONNOR | NPPO | REVIEW | Reqs Change | SECTION 4-02.0.0: FLOODPLAIN, WASH AND ERZ STANDARDS Encroachment in Regulated Areas If the project proposes encroachment within the regulated areas, it shall conform to the following. Environmental Resource Report. Applicants are required to submit an Environmental Resource Report as defined in Section 11.4.6 of the UDC. The supporting material for preparation of the Environmental Resource Report is based on information from the Hydrologic Data and Wash Information maps on the Tucson Department of Transportation internet web site: The Critical and Sensitive Wildlife Habitat Map and Report, the Mayor and Council Interim Watercourse Improvement Policy and subsequent adopted policies, the Tucson Stormwater Management Study, the following Basin Management Plans: 1) West Branch, Santa Cruz; 2) Houghton East; 3) Este Wash; and 4) Arroyo Chico. the Tucson Stormwater Management Study, Phase II and field observation. The Environmental Resource Report must include: Items a-x listed in the code section An application may request that an element listed in the code be waived or that the report address only a specified area where a full report is not applicable to the proposed encroachment. DSD may grant such waivers where the elements or full report are not required by code. Provide ERR for review with next submittal. Ensure that all Engineering comments are addressed. Additional comments may apply. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/11/2018 | KROBLES1 | OUT TO CUSTOMER | Completed |