Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP18-0114
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/14/2018 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principal Planner PROJECT: 4500 N. Oracle Road Development Package (1st Review) DP18-0114 TRANSMITTAL DATE: May 12, 2018 DUE DATE: Walk Through COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 2-06.3.0 FORMAT REQUIREMENTS 1. 2-06.3.2 - Provide the scale of the development package on the plan. 2. 2-06.3.5 - Provide the PDSD Development Package approval stamp in the lower right quadrant of all sheets. The required stamp can be found at http://pdsd.tucsonaz.gov/pdsd/development-permits under Development Package. 3. 2-06.3.7 - The location mat shown in the upper right hand corner is not correct and shows the intersection of Broadway and Kolb. CONTENT REQUIREMENTS 4. 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project shall be provided on the right half of the cover sheet. 5. 2-06.4.2.B - The title block shall include a brief legal description. 6. 2-06.4.2.D - The title block shall include the page number and the total number of pages in the package (i.e., sheet xx of xx). 7. 2-06.4.3 - Provide the development package case number, DP18-0114, adjacent to the title block on all sheets. 8. 2-06.4.3 - Provide the rezoning case number, C9-79-07, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 9. 2-06.4.7.A.4 - Identify the existing and proposed uses of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 10. 2-06.4.7.A.6.a - Provide a general note on the cover sheet stating "THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)." 2-06.4.7.A.8 - For development package documents provide: 11. 2-06.4.7.A.8.a - The floor area listed under "Building tabulations:" for the "DCS" does not match what in shown within the footprint, clarify the difference. Also the total building square footage shown does not match what was shown on the last approved DP17-0175, clarify the difference. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 12. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. 13. 2-06.4.9.G - 14. 2-06.4.9.H.5 - Fully dimension the area within the fenced courtyard type vehicle parking area. 15. 2-06.4.9.H.5.a - There are several vehicle parking spaces that are adjacent to barriers over 6" in height. Clearly demonstrate that the requirements of UDC Article 7.4.6.D.2.b are met. 16. 2-06.4.9.H.5.a - As new vehicle parking is proposed along the west side of the fenced courtyard type vehicle parking area, clearly shown the 2.-6" vehicle overhang on the plan. 17. 2-06.4.9.H.5.a does not appear to accessible vehicle parking, clarify. 18. 2-06.4.9.H.5.a - Detail 2 "Accessible Parking Plan" clearly demonstrate on the detail that the accessible space meets the requirements of ICC A117.1, Section 502.2 such as but not limited to dimensions, markings, grade slopes, accessible parking aisle, signage, van accessible space and access to the accessible route. Provide an accessible sign detail. 19. 2-06.4.9.R - As new vehicle parking is proposed along the south side of the fenced courtyard type vehicle parking area, provide a sidewalk that meets all requirements of TSM 7-01. 20. 2-06.4.9.R - As new vehicle parking is proposed along the west side of the fenced courtyard type vehicle parking area, demonstrate that the minimum 4' sidewalk width is maintained when parking vehicles overhang the sidewalk, see TSM Section 7-01.4.3.A. 21. 2-06.4.9.R - - Detail 1 "Accessible Parking Plan" as it appears that you are routing a new pedestrian way, sidewalk around some type of obstacle, this area will need to be a sidewalk meeting the requirements of TSM Section 7-01.4.3. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 05/14/2018 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | See Zoning comments |