Permit Number: DP18-0107
Parcel: 14026003Q

Address:
5975 S TUCSON BL

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP18-0107
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2018 KELLY LEE START PLANS SUBMITTED Completed
11/02/2018 EHAMBLI1 ZONING REVIEW Approved
11/26/2018 JOHN VAN WINKLE ENGINEERING REVIEW Approved
11/27/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Lots 1, 26, 27, 50, 51, 52, 60, 61, 63, 64, 70, 71, 75, 95, 111, 115, 122, 153, and 155 appear to require backwater valve but do not have them. [Second comment: Lots 1, 50, and 75 appear to require backwater valve but do not have them. Lots 28, 56, 112, 122, 124 do not appear to need backwater valves but are shown as having them. Verify which lots will require the installation of backwater valves.] [Initial comment: Where the finish floor elevation will be less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the backwater valve. Indicate which lots will require the installation of backwater valves. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.]
11/30/2018 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved The Tucson Parks and Recreation Department's comments have been adequately addressed. Approval recommended.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
11/30/2018 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change

Final Status

Task End Date Reviewer's Name Type of Review Description
11/30/2018 SBEASLE1 OUT TO CUSTOMER Completed