Permit Number: DP18-0101
Parcel: 136326730

Review Status: Completed

Review Details: GRADING

Permit Number - DP18-0101
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/15/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: DP18-0101 (Related to T18Cm3027)
Grading Plan for a new Residence (1st Review)
4725 S. Paseo Melodioso

TRANSMITTAL DATE: May 16, 2017

DUE DATE: May 29, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the Grading plan for compliance with zoning requirements. While the proposed development meets the zoning requirements as it relates to coverage, bldg. height, and setbacks, this plan requires approval of the HDZ requirements which must be approved by the PDSD Engineering and NPPO reviewers prior to zoning approval. As of this zoning review date the grading plan has not been approved by either reviewer. The proposed location for the dwelling is within the approved building area as recorded on the Final Plat and is acceptable for approval by zoning once the PDSD Engineer and NPPO Reviewer has reviewed and approved the grading plan.


2. COMMENT: The grading plan can be reviewed and approved over the counter on the next submittal of the grading plan.



If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov
05/25/2018 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Revise the maximum building height to 24 feet. UDC 5.2.7.A
2. Provide cut and fill quantities for the grading permit.

Once these changes have been completed, I will review the plans over the counter.
05/29/2018 ANDREW CONNOR NPPO REVIEW Reqs Change This site is within HILLSIDE DEVELOPMENT ZONE (HDZ)


Provide the following notes on the cover sheet:

Vegetation Retention and Revegetation
a. Vegetation Retention
(1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites.
(2) When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible.
b. Revegetation
All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards:
(1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and,
(2) Revegetation shall be accomplished with the following minimum standards for plants:
(a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and,
(b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD.
(3) A temporary watering system shall be installed until the revegetation materials are established.
3. Slope Stabilization
All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows:
a. Stone riprapping shall be hand-placed on the slope;
b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and,
c. Vegetation retention and revegetation should be used in conjunction with riprapping.

Ensure that Engineering comments are addressed.

Review can be completed over the counter.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/04/2018 LPEREZ2 OUT TO CUSTOMER Completed