Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP18-0082
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/27/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 08/13/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/13/2018 | EHAMBLI1 | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Elisa Hamblin, AICP Lead Planner PROJECT: Radiant Gymnastics Development Package (Conditional Approval) DP18-0082 TRANSMITTAL DATE: August 13, 2018 DUE DATE: August 21, 2018 COMMENTS: Zoning has conditionally approved this development package subject to the minor revisions noted in the comment below. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 2, 2019. 1. Previous comment #6. Correct the zoning boundary for the SR zoned area. It should be approximately in the center of the Golf Link right-of-way. Reference Map Tucson for location. If you have any questions about this transmittal, please contact Elisa Hamblin at (520) 837-4966 or Elisa.Hamblin@tucsonaz.gov. |
| 08/15/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 08/17/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Extending the 8" BCS stub-out onto the private property (keynote #30, sheet 2 of 12) will require the installation of a private manhole. Reference: Section 708.3.2, IPC 2012. [Initial comment: Revise the site drawing to include the rim elevations, invert elevations, and the Pima County Wastewater Management Department (PCWMD) reference number for the sanitary manholes and cleanouts upstream and downstream of the proposed sewer connection points. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012.] |
| 08/20/2018 | KELLY LEE | ZONING-DECISION LETTER | REVIEW | Reqs Change | Lisa: This review has been completed and resubmittal is required. Please resubmit the following items: Prepare a Comment Response Letter which tells the reviewer what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Corrected plan set 2) Items requested by review staff Please remember to name your files appropriately, for example: 3rd submittal, 3_plan_set.pdf 3_swppp_report.pdf and the plans will re-enter the review cycle. Thank you, Kelly Lee Lead Planner Planning & Development Services (520) 837-6999 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/29/2018 | AHINES2 | OUT TO CUSTOMER | Completed |