Permit Number: DP18-0071
Parcel: 11307243A

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP18-0071
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2019 SBEASLE1 START PLANS SUBMITTED Completed
02/14/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved
03/07/2019 DAVID RIVERA ZONING REVIEW Approved
03/19/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change REVISION PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: DP18-0071
Project Description: E SITE/GRADE/SWPPP - Mountain Adelaide FLD Multi-family
To view revision review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
After the necessary corrections have been made, name your documents in the following manner - a 2nd submittal document (first revision) would be titled: REV-1_2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, enter the Activity Number.
1) Comment Response Letter (lists changes to the Plan and which review comments are being addressed)
2) Corrected plan set with all documents (the full set)
3) Items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero). The Project Manager can be reached via email: Maria.Gayosso@TucsonAz.gov or phone: (520) 837-6972. Thank you.
City of Tucson
Planning and Development Services
Attn: Sharon Beasley
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
03/19/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site utility drawing to indicate that backwater valves will be required for buildings 1, 2, 4, 5, 7, and 10 because the rem elevation of the upstream manholes are less than 12" below the proposed first floor elevations. Floors discharging from above that reference point shall not discharge through the backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/18/2019 SBEASLE1 OUT TO CUSTOMER Completed