Permit Number: DP18-0067
Parcel: 11705033A

Address:
314 E 6TH ST

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP18-0067
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2019 SBEASLE1 START PLANS SUBMITTED Completed
05/28/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved (The TEP Facilities Map mentioned here - and Redline Plush Lofts plan - can be viewed on PRO in the "Documents" section)

WR#6227991
May 28, 2019
City of Tucson
Attn: Sharon Beasley
Planning and Development Services
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
Dear Ms. Beasley:
SUBJECT: Union on 6th, DP18-0067
Tucson Electric Power Company (TEP) has reviewed and approved the development plan completed on May 28, 2019. It appears that there are conflicts with the existing TEP facilities within the boundaries of this proposed development.
We have been in contact with architect Burak Bekat. There is are existing overhead poles and lines on Herbert that will need to be relocated/converted to underground. There are new facilities that will be installed on 5th Avenue and Seventh Street right of way. Approval of development plan is contingent on above conflicts being resolved.
Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.
In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.
If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington, New Business Project Manager
P. O. Box 711 (DB101), Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please contact the area Designer, Martin Rodriguez, at (520) 917-8787.
Sincerely,
Linda Metzer, Office Support Assistant
Design/Build
lm
Enc.
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
M. Rodriguez, Tucson Electric Power
06/20/2019 DAVID RIVERA ZONING REVIEW Approved
06/24/2019 SBEASLE1 COT NON-DSD REAL ESTATE Approv-Cond (The TRE Application mentioned here can be viewed on PRO in the "Documents" section)

Should any ground or aerial encroachments into City right-of-way come to be included, applicant is requested to contact the Real Estate Division to apply for easements. Any development in Herbert Ave or in the 4th and 5th Aves and 6th St RoW that cannot be addressed by a PIA should be directed to Real Estate as well.

Railing for stairs along N. 4th Ave are located in the COT right of way and will require a TRE. Application is attached.

Michael J. Hollar
SENIOR PROPERTY AGENT
REAL ESTATE DIVISION
DEPARTMENT OF TRANSPORTATION
CITY OF TUCSON
201 N. Stone Ave, 6th Floor
Tucson, AZ 85701
Direct: 520-837-6784
Main: 520-791-4371
06/24/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Approved PLAN APPROVAL NOTICE / REQUEST FOR DOCUMENTS
Activity Number: DP18-0067
Project Description: E SITE / GRADE / SWPPP / IID - Union on 6th.
Please reply to this email and attach the following documents to obtain a link to the stamped plans and list of required inspections:
1. City of Tucson Permit, check-marked and signed (see attached).
2. Contractor Letter of Intent: Include the project title, project address, Activity Number, ROC license number
3. Fugitive Dust Activity Permit: Contact Pima County DEQ at (520) 724-7400
After we receive these documents, please allow 1-2 business days for our staff to stamp the plans and upload them to PRO.
The fee balance is $0 (zero).
Thank you.

City of Tucson
Planning and Development Services
Attn: Sharon Beasley, Permit Technician
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
06/24/2019 SBEASLE1 COT NON-DSD TDOT Approved After review of the previous submittals, responses, and current plans, TDOT Landscape has no additional comments, and the project is approved.
Thank you,
David Marhefka
da’-vid mär-hef’-ka
Landscape Architect
City of Tucson
Department of Transportation
(o) 520-837-6618, (m) 520-403-5074

Final Status

Task End Date Reviewer's Name Type of Review Description
06/24/2019 SBEASLE1 OUT TO CUSTOMER Completed