Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP18-0051
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 08/29/2018 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 09/11/2018 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 09/11/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Wang's Kitchen Development Package (2ndReview) DP18-0051 TRANSMITTAL DATE: September 11, 2018 DUE DATE: September 24, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is February 23, 2019. 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 1. Follow Up To Previous Comment 5: The administrative address was not added next to the title block of all sheets as requested per the previous comment. 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. PREVIOUS COMMENT 5: Provide the development package case number DP18-0051 adjacent to the title block on each sheet. List the administrative address next to the title block of all plan sheets. 2. Follow Up To Previous Comment 6: A TSMR was requested and granted. The case number was not listed under General note 32. List the case number DS18-11 as requested per the TSMR conditions. 3. Follow Up To Previous Comment 10: The Zoning boundary line was not drawn and labeled on the plans. Add and label the zoning boundary as noted in the previous comment. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. PREVIOUS COMMENT 10: Review the City Of Tucson GIS map and revise the zoning boundary lines along the south side of the parcels. A portion of east parcel is zoned R-2 along the south 16 feet extending out to 4th avenue property line. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/19/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP18-0051 1) Per UDC section 7.4.6.H.1 provide a barrier along the western most property |
| 09/24/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Ensure that all zoning and Enginering comments are addressed. |
| 09/27/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | Plan Returned for Corrections Notice: DP18-0051Project Description: E SITE/GRADING - WANG'S KITCHEN To see reviewer's comments about your plans, please visit https://www.tucsonaz.gov/pro/pdsd/activity_search.You will need to enter the activity number shown above to see comments about the plan. This review has been completed and resubmittal is required. Prepare a Comment Response Letter which tells the reviewers what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd and the plans will re-enter the 20 working day review cycle:1) Corrected plan set2) Items requested by review staff Please remember to name your files appropriately, for example: third (3rd) submittal,3_plan_set.pdf3_response_letter.pdf Alexandra Hines, AICP Lead Planner at Planning and Development Services, City of Tucson 201 N Stone Ave 1st Floor, Tucson, AZ 85701 (520) 837-6975 - alexandra.hines@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/27/2018 | AHINES2 | OUT TO CUSTOMER | Completed |