Permit Number: DP18-0044
Parcel: 127022690

Address:
5324 E 1ST ST

Review Status: Active

Review Details: RESUB - SITE/GRADING ALL

Permit Number - DP18-0044
Review Name: RESUB - SITE/GRADING ALL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2018 ANDREW CONNOR ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Andrew Connor for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: Catalina Village Assisted Living Phase # 3
Development Package (2nd Review)
DP18-0044

TRANSMITTAL DATE: 06/13/18
DUE DATE: 06/19/18

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is 2/20, 2019.

DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.3.0 FORMAT REQUIREMENTS


CONTENT REQUIREMENTS

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

1. COMMENT: Provide the correct land use. Remove and replace reference to Land Use Code with UDC (see redlines pertaining to LUC references)

2-06.4.7.A.8 - For development package documents provide:

2-06.4.9 - Information on Proposed Development

2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements.

2. COMMENT: Provide correct adjacent zoning classifications on site plan (see redlines).

2-06.4.9.H - Proposed Traffic Circulation

2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

3. COMMENT: Show the correct sight visibility triangles on proposed site plan at the entrance drive on Woodland Ave (see redlines Woodland Ave is a two way street) for Sight Visibility Triangle criteria refer to Sec 10-01.5.0 of the TECHNICAL STANDARDS MANUAL.

2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required.

4. COMMENT: Indicate and number all the required parking spaces for the site on Sheet 3 of 9.

2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

5. COMMENT: Label the height, use and square footage within the building footprint of the proposed new building.


2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual.

6. COMMENT: Graphically show on site plan how pedestrian circulation to Woodland Ave will be achieved.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. Over the counter review can be provided.
06/14/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/14/2018 ANDREW CONNOR LANDSCAPE REVIEW Approved
06/15/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP18-0044

1) Engineering will conduct an over the counter approval after the outstanding comments from the Zoning Department have been addressed

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
06/18/2018 ACONNOR1 H/C SITE REVIEW Reqs Change See zoning comments pertaining to accessibility.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/21/2018 ANY REJECT SHELF RECEIVED