Permit Number: DP18-0017
Parcel: 99999999A

Review Status: Completed

Review Details: GRADING

Permit Number - DP18-0017
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: DP18-0017 - La Estancia Phase 2
Grading plans (1st Review)
6861 E. Camino Boleadoras

TRANSMITTAL DATE: February 20, 2018

DUE DATE: February 23, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the Grading plans for Phase 2 but cannot approve them at this time. While the grading plans for phase 8 are consistent with the current revised version of the DP, and as it relates to the zoning review purview zoning will approve the grading plan once the revised DP17-0254 fully approved and the engineering reviewer approves the grading plan.

2. COMMENT: Add the DP stamp to all grading plan sheets for plan reviewer signatures. The digital stamp can be downloaded from the PDSD web site.

3. COMMENT: List the DP case number DP18-0017 in the lower right corner next to the title block of all sheets. Reference the associated revised tentative plat case number DP17-0254 next to the title block of all plan sheets.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email at David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
02/22/2018 ANDREW CONNOR NPPO REVIEW Reqs Change List the DP case number DP18-0017 in the lower right corner next to the title block of all sheets. Reference the associated revised tentative plat case number DP17-0254 next to the title block of all plan sheets.
Ensure that all Engineering comments are addressed.
03/05/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change 1) Sheet 2 note 11 references incorrect geotechnical report. Update to reference report provided, Pattison and Evanoff project no. 13-070 dated 6/28/2018
2) Provide cut/fill quantities on drawings

John Van Winkle, P.E.
john.van-winkle@tucsonaz.gov
520-837-5007

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2018 KROBLES1 OUT TO CUSTOMER Completed