Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP18-0015
Parcel: 99999999A

Review Status: Completed

Review Details: GRADING

Permit Number - DP18-0015
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2018 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: DP18-0015 - La Estancia Phase 8
Grading plans (1st Review)
6861 E. Camino Boleadoras

TRANSMITTAL DATE: February 20, 2018

DUE DATE: February 23, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. COMMENT: Zoning has reviewed the Grading plans for Phase 8 but cannot approve them at this time. While the grading plans for phase 8 are consistent with the current revised version of the DP, and as it relates to the zoning review purview zoning will approve the grading plan once the revised DP17-0254 fully approved and the engineering reviewer approves the grading plan.

2. COMMENT: Add the DP stamp to all grading plan sheets for plan reviewer signatures. The digital stamp can be downloaded from the PDSD web site.

3. COMMENT: List the DP case number DP18-0015 in the lower right corner next to the title block of all sheets. Reference the associated revised tentative plat case number DP17-0254 next to the title block of all plan sheets.

If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email at David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
02/22/2018 ANDREW CONNOR NPPO REVIEW Reqs Change List the DP case number DP18-0015 in the lower right corner next to the title block of all sheets. Reference the associated revised tentative plat case number DP17-0254 next to the title block of all plan sheets.
Ensure that all Engineering comments are addressed.
03/05/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change 1) Sheet 2: Note 11 references Pattison and Evanoff geotechnical engineering evaluation # 99-523 dated 2-25-2000. Supplied report is project # 13-070 dated 6-28-2013. Clarify and update
2) Provide cut/fill quantities on plans
3) Engineering Seal has an expiration date of 6/30/20XX. Update to show actual expiration date

John Van Winkle, P.E.
john.van-winkle@tucsonaz.gov
520-837-5007

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2018 KROBLES1 OUT TO CUSTOMER Completed