Permit Number: DP18-0011
Parcel: 12416103A

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP18-0011
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2018 KROBLES1 START PLANS SUBMITTED Completed
01/19/2018 KELLY LEE UTILITIES SOUTHWEST GAS Passed
01/19/2018 KELLY LEE OTHER AGENCIES PIMA ASSN OF GOVTS Passed
01/19/2018 KELLY LEE OTHER AGENCIES U. S. POST OFFICE Passed
01/31/2018 ALEXANDRA HINES OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approv-Cond January 29, 2018

Kelly Lee
Lead Planner
City of Tucson
Public Works Buildings - 201 North Stone Avenue
Tucson, AZ. 85701

RE: DP18-0011 Elliott Electronics / 1st Submittal, Received January 19, 2018

Dear Ms. Lee,

Thank you for the opportunity to comment on DP18-0011, Elliot Electronics / 1st Submittal; a development package application for an approximately 1.05 acre site, located southeast of the intersection of East 23rd Street and South Tyndall Avenue. The proposed land use is commercial, expanding an existing general equipment and supply wholesaling use.

This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.

The Tucson Airport Authority conditionally approves the subject request contingent upon the following conditions of approval, as noted below. These conditions should be identified in the general notes of the approved development plan.

Conditions of approval:

"According to the FAA Notice Criteria Tool, this project is located in proximity to a navigation facility and could impact navigation signal reception. The applicant shall file Form 7460 with the FAA at least 45 days before construction activities begin for the project. Any cranes which are used must also be identified with Form 7460. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp"

"That prior to the City's approval of any construction permit for a permanent building, the property owner shall record the Avigation Easement which discloses the existence, and operational characteristics of the Tucson International Airport to future owners or tenants of the property and further conveys the right to the public to lawfully use the airspace above the property. The content of such documents shall be according to the form and instructions provided."

The current property owner or person authorized to sign on behalf of the current property owner shall complete, sign, and record the Avigation Easement. Please record the Avigation Easement with the Pima County Recorder's Office. Once the Avigation Easement is recorded please send a copy of the recorded easement to the Tucson Airport Authority by either email (send to srobidoux@flytucson.com) or to the mailing address provided below.



Scott Robidoux
Senior Airport Planner
Tucson Airport Authority
7250 South Tucson Boulevard
Suite 300
Tucson, AZ 85756

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.

Respectfully,


Scott Robidoux,
Senior Airport Planner

cc file
02/06/2018 MARTIN BROWN COT NON-DSD FIRE Approved
02/07/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

February 6, 2018



WR# 6220137

DSD_CDRC@tucsonaz.gov
mulltiples@aol.com

Dear Roger

SUBJECT: Elliot Electronics - 1st Submittal
1301 S Tyndall
DP18-0011

Tucson Electric Power Company has reviewed and approved the development plan.

There are possible conflicts within the existing facilities. Customer to contact TEP and make an application for any relocation or removal of facilities, this will be billable.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer, Steve Garcia @ 917-8739.

Sincerely,
Beth Shelton
Elizabeth "Beth" Shelton
Admin Assistant, Design
02/08/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
02/12/2018 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
02/13/2018 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Elliott Electronic Supply
Development Package (1st Review)
DP18-0011

TRANSMITTAL DATE: February 13, 2018

DUE DATE: February 14, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 16, 2019.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

1. 2-06.4.7.A.1 - Revise General Note 1 to read "EXISTING ZONING R-2 & C-3, PROPOSED ZONING C-3."

2. 2-06.4.7.A.4 - The existing and proposed use listed under General Note 3 should be listed as "BUSINESS EQUIPMENT SUPPLY AND WHOLESALING".

3. 2-06.4.7.A.6.a - This project is located within the Airport Avigation Easement and Disclosure Area and will require review by Scott Robidoux Airport Planner. Contact Kelly Lee, Lead Planner COT at Kelly.Lee@tucsonaz.gov for requirements.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. 2-06.4.9.A - As a lot combination is required and the approved Pima County Combo Request from has been provided remove all interior lot lines shown on the plans.

5. 2-06.4.9.H.5 - As the proposed building expansion is greater than 25% the entire site is required to meet the requirements of UDC Article 7.4. That said provide a fully dimensioned vehicle parking area, existing and proposed.

6. 2-06.4.9.H.5 - Per UDC Article 7.4.6.K an alley cannot provide vehicle access to a commercial use. That said demonstrate how vehicles access will be controlled to and from the alley.

7. 2-06.4.9.H.5.d - It does not appear that the short term bicycle parking calculation is correct. Per UDC Article 7.4.9.B.2.D, A single rack is designed and located to accommodate two bicycles. That said the number provided should be 4.

8. 2-06.4.9.H.5.d - As the proposed building expansion is greater than 25% the entire site is required to meet the requirements of UDC Article 7.4. That said demonstrate that the existing short term bicycle parking meets the requirements of UDC Articles 7.4.9.B.1.e, 7.4.9.B.2.f, .g, .h and 7.4.9.C.2.a.

9. 2-06.4.9.O - The street setbacks listed under "DEVELOMENT PLAN NOTES AND CALCULATIONS" are not correct. This site does not boarder on an MS&R or meet the definition of Developing Area, see UDC Article 11.4.5. The street perimeter yard setbacks should be 20 or 1-1/2 the height of the building exterior wall, greater of the two.

10. 2-06.4.9.R - As the proposed building expansion is greater than 25% the entire site is required to meet the requirements of TSM Section 7-01. That said provide width dimensions for all existing sidewalks and crosswalks on the plan.

11. 2-06.4.9.R - Clarify what the accessible access ramp is for shown along the west side of the proposed addition and called out under keynote 40.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/13/2018 SSHIELD1 HC SITE REVIEW Reqs Change See Zoning comments
02/14/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
The landscape plan will contain the following identification in the lower right corner of each sheet:
Cross-reference to:
a. Rezoning case;
Include any rezoning conditions regarding landscape and demonstrate how conditions are met on the landscape plans.
7.6.2. APPLICABILITY
Buildings 10,000 Square Feet or Less
On sites where the gross floor area of the existing building(s) is 10,000 square feet or less, expansions in square footage of land area, floor area, lot coverage, or vehicular use area as follows.
a. If the expansion is less than 50%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 50% or greater or if expansions as of February 15, 1991, cumulatively result in a 50% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.
Verify building expansion calculation.
If 50% or over the following applies:
Show compliance for the entire site with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-1.0.0, Landscape Plan Requirements.
Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval.
Additional comments may apply.
02/14/2018 ANDREW CONNOR NPPO REVIEW Approved
02/23/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change 1) Per UDC section 7.6.6.C.2 project project site should incorporate water harvesting features where possible - for example the existing parking lot tree islands
2) A Flood Plain Use Permit is required. Project is within a City of Tucson flood zone
3) Add notes to sheet 1 as found in section 2-06.4.7.B.2-3 of the City of Tucson Administrative Manual as project is located within flood zone
4: Show that existing chainlink fence to the south with not impede or obstruct water flow, accounting for accumulation of debris

John Van Winkle, P.E.
john.van-winkle@tucsonaz.gov
520-837-5007
02/26/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
02/27/2018 LPEREZ2 OUT TO CUSTOMER Completed