Permit Number: DP17-0290
Parcel: 10508015F

Address:
4901 N ORACLE RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP17-0290
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2018 LPEREZ2 START PLANS SUBMITTED Completed
03/28/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The plumbing site plan, PSI, does not address the comments. The site plan needs to show where the public water lines and fire hydrants are located, where the building sewer connects to the public sewer, etc. [Initial comment: Revise the site drawing to include the following information:
a. The location water lines and fire hydrants.
b. The location of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number.
c. The points of connection to existing public sewers.
d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights.
Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012.]
03/28/2018 MMORENO1 ZONING REVIEW Approved
03/29/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE

ARTICLE 7: DEVELOPMENT STANDARDS

The landscape plan shall include the following:
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
Include the expansion on the submitted landscape plans, add sheets to the index and add new DP # DP17-290 to all landscape sheets.
04/02/2018 JPEELDA1 COT NON-DSD FIRE Reqs Change Per 2012 International Fire Code, section 507.5, the maximum distance from the furthest part of a building to a fire hydrant is 600', as the hose lays. The existing hydrant is significantly further than 600'. An additional hydrant is required.
04/03/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
04/25/2018 BLARSON1 OUT TO CUSTOMER Completed