Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP17-0290
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/02/2018 | LPEREZ2 | START | PLANS SUBMITTED | Completed | |
| 03/28/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The plumbing site plan, PSI, does not address the comments. The site plan needs to show where the public water lines and fire hydrants are located, where the building sewer connects to the public sewer, etc. [Initial comment: Revise the site drawing to include the following information: a. The location water lines and fire hydrants. b. The location of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. c. The points of connection to existing public sewers. d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights. Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012.] |
| 03/28/2018 | MMORENO1 | ZONING | REVIEW | Approved | |
| 03/29/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | UNIFIED DEVELOPMENT CODE ARTICLE 7: DEVELOPMENT STANDARDS The landscape plan shall include the following: 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Include the expansion on the submitted landscape plans, add sheets to the index and add new DP # DP17-290 to all landscape sheets. |
| 04/02/2018 | JPEELDA1 | COT NON-DSD | FIRE | Reqs Change | Per 2012 International Fire Code, section 507.5, the maximum distance from the furthest part of a building to a fire hydrant is 600', as the hose lays. The existing hydrant is significantly further than 600'. An additional hydrant is required. |
| 04/03/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/25/2018 | BLARSON1 | OUT TO CUSTOMER | Completed |