Permit Number: DP17-0290
Parcel: 10508015F

Address:
4901 N ORACLE RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP17-0290
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2018 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
01/08/2018 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approv-Cond CDRC: DP12-0161 OTHER: C9-82-48 ORD. 5651

Southcentral District Permits: No comments for expansion to Subaru Dealership @ 4901 N. Oracle Rd.

Regional Traffic: No comments for expansion to Subaru Dealership @ 4901 N. Oracle Rd.

Note: plans should have reflected the improvements on SR 77 as existing and not new construction.

Richard La Pierre
Permits Supervisor, South Central District
1221 South Second Avenue
Tucson, Arizona 85713
520.388.4234 (office)
520.307.5893 (cell)
RLaPierre@azdot.gov
01/08/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE

ARTICLE 7: DEVELOPMENT STANDARDS

The landscape plan shall include the following:
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
B. The landscape plan will contain the following identification in the lower right corner of each sheet:
1. Legal description and address of site;
2. Cross-reference to:
Any relevant case number for reviews or modifications that affect the site.

7.6.2. APPLICABILITY
The provisions of this section apply to the following:
A. All new development; and,
B. Expansion of existing development, as provided below:
1. Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:
a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.

The total expansion is 62.6 % provide landscape plan with requirements for the entire site.

Ensure that all Zoning and Engineering comments are addressed.

Additional comments may apply.
01/08/2018 ANDREW CONNOR NPPO REVIEW Approved
01/08/2018 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
01/09/2018 MMORENO1 HC SITE REVIEW Passed
01/09/2018 MMORENO1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Michael Moreno
PDSD Zoning Review Section

PROJECT: Subaru Dichristofano Expansion
Development Package (1st Review)
DP17-0290

TRANSMITTAL DATE: January 9, 2018
DUE DATE: January 9, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 8, 2018.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section

2-06.3.0 FORMAT REQUIREMENTS


1. COMMENT:

2-06.3.2 - All mapped data shall be drawn at an engineering scale having no more than 50 feet to the inch. This scale is the minimum accepted to assure the plan will be legible during review and when digitized and/or reduced for record-keeping purposes. The same scale shall be used for all sheets within the set. Smaller scales (60:1 or greater) may be used for some or all of the sheets with the prior approval of PDSD when it is determined legibility and the ability to be digitized and/or reduced for archiving will not be affected.

2. COMMENT: Please provided the same scale per every sheet of the development package.


2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet.

3. COMMENT: Provide a title block per Page 7 & 8.

2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp.

4. COMMENT: Please provide a three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet 7 & 8 for an approval stamp.



2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet.

5. COMMENT: Provide north arrow, contour interval, and scale as applicable to sheet 7 & 8 which should be placed together in the upper right corner of each sheet

CONTENT REQUIREMENTS


2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

6. COMMENT: Provide the development package case number, DP17-0290, adjacent to the title block on each sheet.


2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

7. COMMENT: Please label and indicate parking space locations on the plan. Verify which customer (parking spaces) will be used for the existing and proposed buildings. Draw and label accessible parking signs at accessible parking spaces. Provide a dimension detail of accessible parking sign.


2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown.

8. COMMENT: Provide building setback for the new detailing building to the south property line. In order to verify setbacks label the building the height of the


2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

9. COMMENT: In order to verify all setback label the height of each commercial structure and the specific use proposed within the footprint and provide building height for all new structures.



2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

10. COMMENT: Please provide on-site pedestrian circulation including cross walks and sidewalks connecting the property building.


2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping.

11. COMMENT: Please Label were the proposed mailboxes or new mailboxes will be for the new buildings.


2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required.

12. COMMENT: All proposed and new sings will have to go through the permit process and will require a new permit.




RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/16/2018 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed Agency notified for information only.
01/17/2018 LOREN MAKUS ENGINEERING REVIEW Approved
01/18/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
12/08/2017 KROBLES1 START PLANS SUBMITTED Completed
12/13/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site drawing to include the following information:
a. The location water lines and fire hydrants.
b. The location of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number.
c. The points of connection to existing public sewers.
d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights.
Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012.
12/14/2017 MARTIN BROWN COT NON-DSD FIRE Reqs Change Please indicate location of existing and or proposed fire hydrants. Refer to section 507 of the 2012 International Fire Code for spacing requirements. Also, if the intent is to provide fire sprinklers, please show proposed location of fire service underground.
12/20/2017 ALEXANDRA HINES UTILITIES SOUTHWEST GAS Passed Agency notified for information only.
12/20/2017 ALEXANDRA HINES OTHER AGENCIES PIMA ASSN OF GOVTS Passed Agency notified for information only.
12/20/2017 ALEXANDRA HINES OTHER AGENCIES U. S. POST OFFICE Passed Agency notified for information only.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/02/2018 LPEREZ2 APPROVAL SHELF Completed
03/02/2018 LPEREZ2 OUT TO CUSTOMER Completed
03/02/2018 LPEREZ2 REJECT SHELF Completed