Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP17-0290
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2018 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 01/08/2018 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approv-Cond | CDRC: DP12-0161 OTHER: C9-82-48 ORD. 5651 Southcentral District Permits: No comments for expansion to Subaru Dealership @ 4901 N. Oracle Rd. Regional Traffic: No comments for expansion to Subaru Dealership @ 4901 N. Oracle Rd. Note: plans should have reflected the improvements on SR 77 as existing and not new construction. Richard La Pierre Permits Supervisor, South Central District 1221 South Second Avenue Tucson, Arizona 85713 520.388.4234 (office) 520.307.5893 (cell) RLaPierre@azdot.gov |
| 01/08/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | UNIFIED DEVELOPMENT CODE ARTICLE 7: DEVELOPMENT STANDARDS The landscape plan shall include the following: 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. B. The landscape plan will contain the following identification in the lower right corner of each sheet: 1. Legal description and address of site; 2. Cross-reference to: Any relevant case number for reviews or modifications that affect the site. 7.6.2. APPLICABILITY The provisions of this section apply to the following: A. All new development; and, B. Expansion of existing development, as provided below: 1. Buildings Greater Than 10,000 Square Feet On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows: a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval. b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site. The total expansion is 62.6 % provide landscape plan with requirements for the entire site. Ensure that all Zoning and Engineering comments are addressed. Additional comments may apply. |
| 01/08/2018 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 01/08/2018 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this development. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 01/09/2018 | MMORENO1 | HC SITE | REVIEW | Passed | |
| 01/09/2018 | MMORENO1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael Moreno PDSD Zoning Review Section PROJECT: Subaru Dichristofano Expansion Development Package (1st Review) DP17-0290 TRANSMITTAL DATE: January 9, 2018 DUE DATE: January 9, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 8, 2018. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.3.0 FORMAT REQUIREMENTS 1. COMMENT: 2-06.3.2 - All mapped data shall be drawn at an engineering scale having no more than 50 feet to the inch. This scale is the minimum accepted to assure the plan will be legible during review and when digitized and/or reduced for record-keeping purposes. The same scale shall be used for all sheets within the set. Smaller scales (60:1 or greater) may be used for some or all of the sheets with the prior approval of PDSD when it is determined legibility and the ability to be digitized and/or reduced for archiving will not be affected. 2. COMMENT: Please provided the same scale per every sheet of the development package. 2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet. 3. COMMENT: Provide a title block per Page 7 & 8. 2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. 4. COMMENT: Please provide a three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet 7 & 8 for an approval stamp. 2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 5. COMMENT: Provide north arrow, contour interval, and scale as applicable to sheet 7 & 8 which should be placed together in the upper right corner of each sheet CONTENT REQUIREMENTS 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 6. COMMENT: Provide the development package case number, DP17-0290, adjacent to the title block on each sheet. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 7. COMMENT: Please label and indicate parking space locations on the plan. Verify which customer (parking spaces) will be used for the existing and proposed buildings. Draw and label accessible parking signs at accessible parking spaces. Provide a dimension detail of accessible parking sign. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. 8. COMMENT: Provide building setback for the new detailing building to the south property line. In order to verify setbacks label the building the height of the 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 9. COMMENT: In order to verify all setback label the height of each commercial structure and the specific use proposed within the footprint and provide building height for all new structures. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 10. COMMENT: Please provide on-site pedestrian circulation including cross walks and sidewalks connecting the property building. 2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping. 11. COMMENT: Please Label were the proposed mailboxes or new mailboxes will be for the new buildings. 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required. 12. COMMENT: All proposed and new sings will have to go through the permit process and will require a new permit. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 01/16/2018 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Passed | Agency notified for information only. |
| 01/17/2018 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 01/18/2018 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
| 12/08/2017 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 12/13/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise the site drawing to include the following information: a. The location water lines and fire hydrants. b. The location of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. c. The points of connection to existing public sewers. d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights. Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012. |
| 12/14/2017 | MARTIN BROWN | COT NON-DSD | FIRE | Reqs Change | Please indicate location of existing and or proposed fire hydrants. Refer to section 507 of the 2012 International Fire Code for spacing requirements. Also, if the intent is to provide fire sprinklers, please show proposed location of fire service underground. |
| 12/20/2017 | ALEXANDRA HINES | UTILITIES | SOUTHWEST GAS | Passed | Agency notified for information only. |
| 12/20/2017 | ALEXANDRA HINES | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | Agency notified for information only. |
| 12/20/2017 | ALEXANDRA HINES | OTHER AGENCIES | U. S. POST OFFICE | Passed | Agency notified for information only. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/02/2018 | LPEREZ2 | APPROVAL SHELF | Completed |
| 03/02/2018 | LPEREZ2 | OUT TO CUSTOMER | Completed |
| 03/02/2018 | LPEREZ2 | REJECT SHELF | Completed |