Permit Number: DP17-0223
Parcel: 107122640

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Permit Number - DP17-0223
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2018 QJONES1 START PLANS SUBMITTED Completed
05/09/2018 EHAMBLI1 ZONING HC REVIEW Approved
05/09/2018 KELLY LEE UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the tentative plat submitted on May 2, 2018. An additional lot has been added since the initial electrical design was provided, therefore the electrical plan will change, and may not coincide with the proposed electric equipment locations shown on the tentative plat.



Please contact me at 520-917-8744 with any questions.



Thank you,



Mary Burke

Right of Way Agent III

Tucson Electric Power Co.

Land Resources – RC 131

3950 E. Irvington Road

Tucson, AZ 85714-2114

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
05/09/2018 EHAMBLI1 ZONING REVIEW Approved
05/09/2018 KELLY LEE PIMA COUNTY WASTEWATER Passed Pima County Wastewater requires separate submittal to Pima County. Email sewer@pima.gov for information.
05/11/2018 ANDREW CONNOR LANDSCAPE REVIEW Approved
05/17/2018 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved DP17-0223/ Raena Mae Homes FLD Tentative Plat/ 2nd Submittal is Approved by Pima County Addressing.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
05/18/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The revised first floor elevations and the new upstream manhole results in only lot 2 in need of a backwater valve (2364.30 FFE, 2363.35 rim elevation). Do not install backwater valves if the FFE is 12" or more above the rim of the next upstream manhole. [Initial comment: Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the backwater valve. No private sewer collection system is shown so based on the rim elevation of public manhole 9444-25; lots 2, 3, 4, 5, and 6 will require the installation of a backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.]
05/25/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
05/25/2018 LOREN MAKUS ENGINEERING REVIEW Reqs Change Complete the Differential Grading Process.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/10/2018 QJONES1 APPROVAL SHELF Completed
07/10/2018 QJONES1 OUT TO CUSTOMER Completed
07/10/2018 QJONES1 REJECT SHELF Completed