Permit Number: DP17-0182
Parcel: 121090030

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP17-0182
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2017 ARUIZ1 START PLANS SUBMITTED Completed
08/01/2017 ALEXANDRA HINES UTILITIES SOUTHWEST GAS Passed Notified agency for information only, no response needed from agency.
08/01/2017 ALEXANDRA HINES OTHER AGENCIES U. S. POST OFFICE Passed Notified agency for information only, no response needed from agency.
08/01/2017 ALEXANDRA HINES OTHER AGENCIES PIMA ASSN OF GOVTS Passed Notified agency for information only, no response needed from agency.
08/02/2017 SSHIELD1 H/C SITE REVIEW Reqs Change See Zoning Review comments,
08/02/2017 ALEXANDRA HINES PIMA COUNTY WASTEWATER Reqs Change *IMAGES CAN BE VIEWED IN THE DOCUMENTS TABLE ON PRO.*

August 2, 2017

To: Anthony Boone
Rick Engineering Co.

____________________________________
From: Hussein Al Zubaidi, RWRD (520) 724-6404

Subject: PIMA MIDICAL INSTITUTE
P17WS00068 (DP17-0182) TP-1ST Submittal

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer design for the above-referenced project. The Pima County Regional Wastewater Reclamation Department has found the following deficiencies in the above referenced submittal of the Preliminary Sewer Layout (PSL), based upon PCRWRD Engineering Design Standards (EDS) 2016.

1- All Sheets: Call out all sewer structural information (rim & invert elevation, slope, flow direction and IMS #'s for manholes) for the existing and proposed public sewer.

2- Relocate proposed public sewer MH#1 to the south to be located on the paved entrance for RWRD maintenance truck easy access.*

3- Relocate proposed public sewer MH#2 to the south to be located on the paved entrance for RWRD maintenance truck easy access.*

4- PCRWRD will approve a block-out on new public manhole for future connection, any proposed stub-out are not acceptable (proposed public MH#2).



This office will require a revised set of plans, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. All comments cited in this letter are based upon PCRWRD Engineering Design Standards 2016 and PCRWRD Standard Specifications and Details for Construction 2016.

No additional review fees will be required.


If you have any questions regarding this matter please contact me at your convenience.

Cc. Lorenzo Hernandez, P.E., RWRD
Tom Porter, P.E., RWRD
Francisco Galindo, P.E., RWRD
08/02/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Pima Medical Institute
Development Package (1st Review)
DP17-0182

TRANSMITTAL DATE: August 2, 2017

DUE DATE: August 4, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 31, 2018.

2-06.4.0 CONTENT REQUIREMENTS

1. 2-06.4.2.C - Provide the number of lots proposed within the title block, i.e. 'LOTS 1 - 14".

2. 2-06.4.3 - Provide the development package case number, DP17-0 182, adjacent to the title block on sheets 33 - 54.

3. 2-06.4.3 - Provide the Administrative street address adjacent to the title block on all sheets.

4. 2-06.4.5 - When the development package documents consists of more than one sheet, a sheet index (a legible drawing of the site showing the area represented on each sheet) is to be placed on the cover sheet or the second sheet.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

5. 2-06.4.7.A.3 - Provide the rezoning case number, C9-16-16, adjacent to the title block on sheets 33 - 54.

6. 2-06.4.7.A.3 - Once approved provide the approval date for the rezoning within DEVELOPMENT PLAN GENERAL Note 8.

7. 2-06.4.7.A.3 - Until the final rezoning conditions are provided the conformance to the conditions cannot be verified and the development package cannot be approved.

8. 2-06.4.7.A.4 - Clarify what type of "MEDICAL SERVICES" use you are proposing.

9. 2-06.4.7.A.4 - Under DEVELOPMENT PLAN GENERAL Note 3 and SITE & BUILDING TABULATIONS note 1 you list a use of "INSTITUTIONAL SCHOOL" the UDC does not have a use of institutional school. Should this not be instructional school.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

10. 2-06.4.9.A - Clearly show all proposed lot lines with approximate distances and measurements on sheets 4 -7.

11. 2-06.4.9.H.5 - Per UDC Article 7.4.6.F.2.a.(1) show the required 1'-0" setback from the proposed covered parking to the PAAL.

12. 2-06.4.9.H.5 - Sheet 5 second PAAL west of building 4 provide a width dimension.

13. 2-06.4.9.H.5.a - It does not appear that the vehicle parking space calculation is correct. Clarify where the 1/200 for all proposed uses is coming from.

14. 2-06.4.9.H.5.a - Detail "K" Sheet 17 does not address the requirements for van accessible access widths, see ICC A117.1-2009 Section 502. For you information truncated domes are not required on site.

15. 2-06.4.9.H.5.c - The loading space calculation for the "CIVIC USE GROUP" is not correct. Per UDC Table 7.5.5-A the only use within the Civic Use Group required to provide a loading space is "Civic Assembly".

16. 2-06.4.9.H.6 - Clearly demonstrate how vehicles will be restricted from entering unimproved areas of Phase 2 &3.

17. 2-06.4.9.I - Clearly show the new east property line along Craycroft Road as dedication is required per the rezoning. This dedication will need to be completed prior to approval of the development package.

18. 2-06.4.9.R - Demonstrate that all existing ramps called out under Grading Keynote 2 meet all requirements of the ICC A117.1-2009 Section 405.

19. 2-06.4.9.R - Sheet 5 the accessible route shown running between Building 3 & 4, the area between the double rows of vehicle parking is required to be a sidewalk physically separated from the vehicle parking spaces.

20. 2-06.4.9.W - The proposed monument sign shown at the main vehicle entrance off of Craycroft Road appears to be within the future SVT.

If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
08/02/2017 ALEXANDRA HINES PIMA COUNTY ADDRESSING Reqs Change *The '1_DP17-0182_Pima Medical_Addressing' attachment can be viewed in the Documents table on PRO.*

DP17-0182 Pima Medical Institute / 1st Submittal is being Returned for Corrections by Pima County Addressing.

The attached pdf* contains Addressing’s comments.

Please let me know if you have any questions.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
08/03/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Needs Review *TEP will provide comment as soon as possible.*


TEP will be unable to complete the review in 3 days.

Thank you,

Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
08/03/2017 JVINCEN1 COT NON-DSD FIRE Approved
08/03/2017 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved December 8, 2016

The Planning Center
110 S Church St, Ste 6320
Tucson, AZ 85701

Attn: Lexy Wellott

SUBJECT: Water Availability for project: 2120 N. Beverly Ave, APN: 121090030,
Case #: WA2087, T-14, R-14, SEC-02, Lots: 9999, Location Code: TUC, Total Area: 19.5ac Zoning: R-1

WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson Water has an assured water supply (AWS) designation from the State of Arizona Department of Water Resources (ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject project.

WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an application is received. The developer shall be required to submit a water master plan identifying, but not limited to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed Connection Points to Existing Water System; and 5) Easements/Common Areas.

Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be financially responsible for modifying or enhancing the existing water system to meet those needs.

This letter shall be null and void two years from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.

If you have any questions, please call New Development at 791-4718.

Sincerely,


Richard A. Sarti, P.E.
Engineering Manager
Tucson Water Department

RS:ka
CC:File
08/03/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
08/03/2017 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
08/03/2017 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
240 N. Stone Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR

TO: City of Tucson Development Services

FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office
(520)724-4387

DATE: August 3, 2017

RE: Assessor's Review and Comments Regarding Tentative Plat-
DP17-0182 Pima Medical Institute/1st Submittal (Amended)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
__X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" The title block must be in the lower right hand corner. It must have the number of Lots or Units or Blocks or any combination of these. It must have the common areas listed, if there are any. It must have the Section, Township and Range and if it is a resubdivision, it must mention the plat name and the Map and Plat.

" There must be bearings and dimensions for the perimeter and all lot lines and all common areas.

" Ownership must match what we have. We show Tucson School District No. 1 and not Pima Medical Institute.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
08/03/2017 JOHN BEALL COT NON-DSD URBAN PLANNING & DESIGN Approved
08/04/2017 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change 4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
B. The landscape plan will contain the following identification in the lower right corner of each sheet:
1. Legal description and address of site;
2. Cross-reference to:
a. Rezoning case;
List the applicable rezoning file number and conditions of approval. Also place the C9-__-__ (if applicable) and the plan/plat file numbers in the lower right corner of each sheet.
b. Subdivision case;
c. Board of Adjustment case;
d. Design Development Option case;
e. Development Review Board (DRB) case; and/or,
f. Any other relevant case number for reviews or modifications that affect the site.
Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval.
Additional comments may apply.
08/04/2017 LOREN MAKUS ENGINEERING REVIEW Reqs Change DP17-0182
1. Include final rezoning conditions on the plan.
2. The "Grading Notes", "Paving Notes" and "Grading and Paving Notes" have many similar notes. Please remove the redundant or repetitive notes.
3. Provide curb opening for all planted islands and direct runoff there to the maximum extent practicable.
08/04/2017 AHINES2 NPPO REVIEW Approved
08/04/2017 TOM FISHER COT NON-DSD TDOT Reqs Change I reviewed the plans to check the proposed Sun Tran bus stop and have the following comments:

--a new concrete pad and shelter is being provided as shown on the plans, and it meets the original requirements for the rezoning

--the proposed location of the plan is shown about 60 feet north of the existing crosswalk at Waverly Street. The TDOT's guidelines for placement of bus stops is no closer than 100 feet in front of a crosswalk due to visibility concerns for pedestrian safety, however, this location may work. The alternative is the place the bus stop and shelter farther north adjacent to Building #5 along Craycroft. I would like to consult Sun Tran staff and TDOT Traffic Engineering staff before making this decision.

Other that those items, the plans look good for transit facilities.

Thomas Fisher
Project Manager
City of Tucson Dept. of Transportation
201 N. Stone, 5th Floor
Tucson, AZ 85726-7210
phone (520) 837-6752
tom.fisher@tucsonaz.gov
08/04/2017 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed (except for TEP and Traffic) and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
08/09/2017 ALEXANDRA HINES COT NON-DSD TRAFFIC Approved August 9, 2017
ACTIVITY NUMBER: DP17-0182
PROJECT NAME: Pima Medical Institute
PROJECT ADDRESS: 2121 n Craycroft
PROJECT REVIEWER: Zelin Canchola TDOT


1. At time of construction in the right of way a private improvement agreement will be required from TDOT.


If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2017 QJONES1 APPROVAL SHELF Completed
08/29/2017 QJONES1 OUT TO CUSTOMER Completed
08/29/2017 QJONES1 REJECT SHELF Completed