Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP17-0181
Parcel: 117141430

Address:
450 S MEYER AV

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP17-0181
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2017 KELLY LEE OTHER AGENCIES U. S. POST OFFICE Passed Informational Purposes Only.
07/31/2017 KELLY LEE UTILITIES SOUTHWEST GAS Passed Informational Purposes only.
07/31/2017 ALEXANDRA HINES START PLANS SUBMITTED Completed
07/31/2017 KELLY LEE OTHER AGENCIES PIMA ASSN OF GOVTS Passed Informational Purposes Only.
08/03/2017 AHINES2 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved August 2, 2017

EXA Architects
4544 E. Fort Lowell #146
Tucson, AZ 85712

Attn: Delia Martinez

SUBJECT: Water Availability for project: 450 S. Meyer Ave, APN: 117141440, 11714146A, 117141450, 117141430, 117141550, Case #: WA2251, T-14, R-13, SEC-13, Lots: 1-2,5, Location Code: TUC, Total Area: 1.3ac Zoning: HC-3

WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson Water has an assured water supply (AWS) designation from the State of Arizona Department of Water Resources (ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject project.

WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an application is received. The developer shall be required to submit a water master plan identifying, but not limited to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed Connection Points to Existing Water System; and 5) Easements/Common Areas.

Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be financially responsible for modifying or enhancing the existing water system to meet those needs.

This letter shall be null and void two years from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.

If you have any questions, please call New Development at 791-4718.

Sincerely,

Richard A. Sarti, P.E.
Engineering Manager
Tucson Water Department

RS:ka
CC:File
08/04/2017 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Regional Traffic Engineering has no comments on this submittal and supports its acceptance.

The development’s location may have no significant influence to nearby ADOT facilities. Thank you. TM.

Tom Martinez <TMartinez@azdot.gov>
08/04/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Reqs Change Tucson Electric Power Co., (TEP) is unable to approve the Tentative Plat at this time. Please provide the entire set of plans and a title report for the project.

If you have any questions, please contact me at 520-917-8744.

Thank you,

Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
08/07/2017 AHINES2 PLUMBING-COMMERCIAL REVIEW Needs Review
08/07/2017 AHINES2 H/C SITE REVIEW Needs Review
08/07/2017 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change
08/07/2017 AHINES2 LANDSCAPE REVIEW Needs Review
08/07/2017 ALEXANDRA HINES ZONING REVIEW Needs Review
08/07/2017 ALEXANDRA HINES COT NON-DSD TRAFFIC Needs Review
08/07/2017 ALEXANDRA HINES PIMA COUNTY WASTEWATER Needs Review
08/07/2017 AHINES2 ENGINEERING REVIEW Needs Review
08/07/2017 ED ABRIGO PIMA COUNTY ASSESSOR Needs Review
08/07/2017 ALEXANDRA HINES COT NON-DSD FIRE Needs Review
08/07/2017 ALEXANDRA HINES PIMA COUNTY ADDRESSING Reqs Change *See attachment in Documents folder on PRO.*

DP17-0181 Kennedy & Meyer Townhomes / 1st Submittal is being Returned for Corrections by Pima County Addressing.

The attached pdf* contains Addressing’s comments.

Please let me know if you have any questions.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
08/07/2017 JANE DUARTE COT NON-DSD PARKS & RECREATION Needs Review
08/07/2017 ALEXANDRA HINES OTHER AGENCIES TUCSON AIRPORT AUTHORITY Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/06/2017 QJONES1 APPROVAL SHELF Completed
10/06/2017 QJONES1 OUT TO CUSTOMER Completed
10/06/2017 QJONES1 REJECT SHELF Completed